2
2
II. Specification
1. Model nomenclature
MW C HR W -
- Z A / P S (
)
Source medium
MA: Air source
MW: Ground source
Function of the unit
C: Air cooling
R: Air heating
CH: Air cooling and hot water
CR: Air cooling and heating
CHR: Air (cooling) and hot water
Energy exchange medium
A: Refrigerant W: Water
Z: Integrated type W: Split type(indoor unit )
P: With built in pump, (without built in pump omitted)
S: 3phase(single phase omitted)
A: Horizontal fan direction B: Upward fan direction
Design alternative serial number
The figure represents the horse power of unit
eg:010 means 1 horse power
4. Product work principle(The dotted line in the box only heat recovery models.)
4. Product work principle(The dotted line in the box only heat recovery models.)
F l o o r
surface
F l o o r
surface
Under ground loop
Under ground loop
4-way vavle
4-way vavle
Fan coil
Fan coil
55
55
Tank
Tank
Pump
Pump
Expansion valve
Expansion valve
Compressor
Compressor
Exchanger
Exchanger
Exchanger
Exchanger
Pump
Pump
Multi-Function Water To Water Heat Pump
MACON