background image

2.Electrical connection diagram

2.1.S

trong current connection diagram 

R

e

d

 

W

h

it

e

R

e

d

 

B

lu

e

R

e

d

 

B

lu

e

B

lu

e

Air condition  cycle pump

Ground source  cycle pump

(Power supply input
380V/3ph/50hz)

(220V/1ph/50hz power output)

R

e

d

 

B

lu

e

R

e

d

 

B

lu

e

R

e

d

 

B

lu

e

3-Way valve

Solar cycle pump

Hot water  cycle pump

Solar collector  temperature sense

Air condition electric heater  temperature protect switch

Mk3052 Controller

Mk3051

Room 1

Turn ON/OFF

Room 2

Room N

220V/50HZ

Electricity drive 
3-way valve

Relay

Fan coil temperature 
control switch

L
N

Hot water tank temperature sense

Hot water  electric heater  temperature protect switch

(Fan coil net switch)

13

13

Multi-Function Water To Water Heat Pump

MACON

2.2.control signal 

connection diagram 

Summary of Contents for MWCRW045Z

Page 1: ...Macon Cooling and Heating Energy efficient Equipment Co Ltd Macon Cooling and Heating Energy efficient Equipment Co Ltd MULTI FUNCTION WATER TO WATER MACON MACON...

Page 2: ...nstallation diagram 6 Installation of the temp detector 7 Electrical wiring 8 Electrical Wire Selection 9 Trial run 10 IV Function diagram of the remote controller Controller parameter Table V Mainten...

Page 3: ...the neutral and or tap water pipe 2 4 The wire must be joined in compliance with the requirements of the wiring chart Do not alternate and or repair the unit personally 2 5 The water temperature will...

Page 4: ...mitted A Horizontal fan direction B Upward fan direction Design alternative serial number The figure represents the horse power of unit eg 010 means 1 horse power 4 Product work principle The dotted l...

Page 5: ...ressor Compressor Qty Noise Water Flow Volume Water Pressure Drop Water Connection Water Flow Volume Water Pressure Drop Water Connection Water Flow Volume Water Pressure Drop Water Connection Refrige...

Page 6: ...2 10 12 40 2 10 12 40 2 1500 980 1080 1600 1060 1220 400 450 450 500 250Z S 70 4 240200 91 5 312300 1875 23 20 22 04 40 7 38 7 380 3 50 3 0 0 05 Scroll 4 56 10 12 40 2 10 12 40 2 10 12 40 2 1500 980...

Page 7: ...Dimensions Dimensions MACON MACON MACON Multi Function Water To Water Heat Pump 3 Product appearance and installation dimension 1 Installation dimensions of integrated type unit 5 5...

Page 8: ...ing install the installation place is a solid foundation must be bear the weight of the tank when full of water 2 3 Around the water tank as well as water pipes and hot water pipes should install a va...

Page 9: ...filter to reduce the water system resistance loss 5 7 The unit air conditioning side and the hot water side which connect to running water must be installed a one way valve filter and pressure relief...

Page 10: ...ensure that the unit s maximum starting current requirements 7 3 The unit power supply circuit must have a grounding wire which should connect with a reliable external ground wire and the external gr...

Page 11: ...line of board in the electrical box 7 8 Unit control panel Code MK3051 Fuse specifications 5A 250V 8 Electrical Wire Selection 8 1 Voltage drop occur may due to the large current draw during compress...

Page 12: ...Z S 200Z S 200Z S 300Z S 450Z S 220V 1PH 50Hz 2 2 5mm 2 mm 380V 3PH 50Hz 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 4 0mm 2...

Page 13: ...art the hot water side air conditioning side solar side circulating pump opened the exhaust valve again to drain the pipe air observe and listen water pump operation the circulating water flow whether...

Page 14: ...d be equipped with automatic exhausted valve which is in stalled at the highest of the water system refer to the pipe connection explanation The factory 12 12 Multi Function Water To Water Heat Pump M...

Page 15: ...cle pump Hot water cycle pump Solar collector temperature sense Air condition electric heater temperature protect switch Mk3052 Controller Mk3051 Room 1 Turn ON OFF Room 2 Room N 220V 50HZ Electricity...

Page 16: ...r Prg Prg Ese Ese UNIT ON OFF SET BACK UP DOWN ENTER Press this button to control the unit s ON or OFF Press this button to enter the main menu interface Press this button to return to the previous sc...

Page 17: ...ating inlet temp Hot water mode Hot water temp H W Aux Heating A C Aux Heating Cooling 12 40 on 55 on off off Prg Prg Ese Ese Main menu Maintenance Clock Under the main interface press enter into para...

Page 18: ...inlet G S water outlet 40 45 55 65 13 13 50 13 MACON Prg Prg Ese Ese H W aus Heater Comp Oil Heater 3 way valve on off on off on off Prg Prg Ese Ese A C flow sw G S flow sw H W flow sw Sys1 HP sw Sys...

Page 19: ...e Ese 6 1 A C Pump 6 2 Hot Water Pump 6 3 G S Water Pump 6 4 Solar Pump on off on off on off on off Select Heat pump Select Defrost Select Aux heating Select Pump testing Select Systems Prg Prg Ese Es...

Page 20: ...e value press the key again confirm and exit press the to return the layer menu Ese Ese 3 When you select Timer on press the key regular on or off setting flash press key to modify the boot time wheth...

Page 21: ...lve on off Fan motor on off air condition cycle water pump on off Hot water cycle pump on off Solar cycle pump on off measured value measured value Actual state Actual state Actual state Actual state...

Page 22: ...pump on off air condition cycle water pump on off Hot water cycle pump on off Solar cycle pump on off measured value measured value Actual state Actual state Actual state Actual state Actual state Act...

Page 23: ...m 2 double system A to W W to W 50 50 30 125 1 50 2 99 10 30 Normal Special On off On off A C H W 1 W to W 15 48 10 Special Off Factory setting Adjustable Factory setting Factory setting Adjustable Ad...

Page 24: ...is open or short circuit The sensor is open or short circuit The sensor is open or short circuit The sensor is open or short circuit The sensor is open or short circuit The sensor is open or short cir...

Reviews: