1
2
4
3
34
WINDOWS ·
DOORS
· SLIDING DOORS
Button for button impulse
Transformer
Plug & Play connector /
cable installation
1
Brown: motor operating voltage
minus -
2
White: motor operating voltage
plus +
3
Green: control voltage* minus -
4
Yellow Control voltage * plus +
* The control voltage is required for push-button
(button impulse) and toggle switch (activation/
deactivation of day-release)!
Loop for
Assembly
tension release
White +
Brown -
Gr
ee
n -
Yel
lo
w +
Cable transition
2.5 m door leaf /
6 or 10 m
outer installation
length
12 - 24V DC
min. 1.5 A
openDoor Access Solutions
circuit diagram button impulse
Electrical connections (connection of power supply, connection cable 0.15 m and 10 m) may only be
carried out by authorised personnel!