2. CHANGE THE BATTERY
• Battery type: Lithium CR2, 3V/1400mAh.
• Change the battery like below when the battery signal is flashing on the display.
• Remove the protector cover, unscrewing the screw.
• Change the battery and screw the lid on again.
USER BUTTONS
The turbine digital meter features two buttons (MOVE and RESET) which individually perform
two main functions and together, other secondary functions.
The main functions performed are:
For the reset key, resetting the partial Register and reset table total (reset total).
For the move key, entering instrument calibration mode.
Used together, the two keys permit entering configuration mode,
BATTERY REPLACEMENT
When replacing the battery, please open the cover, remove the plug and replace the battery.
LCD DISPLAY
KEY
①
Partial register (5 figures with moving comma from 0.1 to 99999)
Indicating the volume dispensed since the reset button was last pressed.
②
Indication of battery charge
③
Indication of calibration mode
④
Indication of resetting present total to Zero
⑤
Total register
⑥
Indication of flow rate mode
⑦
Indication of unit of measurement of partial: L= Litres
GAL = Gallons
PT = Pints
QT = Quarts
DAILY USE
BUTTON USAGE, CALIBRATION AND MEASUREMENT
UNIT CHANGE
• Reset the present total (See Fig. 4)
1) When the meter is on standby, press the RESET key.
2) The display shows all the segments.
3) The meter resets the present total already.
Fig. 4