Macnaught OCVF-001 Instruction Manual Download Page 10

LIMITED WARRANTY

1. Macnaught warrantees this product against defects in material and craftsmanship, for a 

period of 3 years from date of purchase, but not including wearing parts.

2. Macnaught’s liability is limited to replacement or repair of defective material within the 

warranty period, when returned freight prepaid to the distributor or their designated service 

depot.

3. The warranty does not cover damage caused by accident, misuse or faulty installation.

4. The product must be installed and maintained in compliance with the instructions.

EXPLODED AND PARTS LIST

METER

Part No.

2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
2-9

Description
Rubber Protector
Meter Cover
Main Circuit Board
Fix Board
Seat
Magnetic Rod
Oval Gear
O-ring
Meter Holder

* Wearing Parts.

Q’ty

1
1
1
1
1
2
2
1
1

2-10
2-11
2-12

2-13*

2-14
2-15
2-16
2-17

Screw
Label
Screw
Battery 
Battery Cover
Screw
Screw
Shaft

4
1
4
1
1
4
4
2

E8

TECHNICAL

DETAILS

EXPLODED AND

PARTS LIST

INSTALLATION

MAINTENANCE

DETAILS OF OPERATION

TROUBLE 

SHOOTING GUIDE

LIMITED

WARRANTY

Summary of Contents for OCVF-001

Page 1: ...fore operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read...

Page 2: ...ere are certain applications for which this equipment was designed It will do the job better and more safely at the capacity for which it was intended Do not modify this equipment and do not use this...

Page 3: ...rection factor to decide the right connection factor then set the proper correction factor refer to 3 Button usage part Once the meter has been installed please make sure that no air pressure shocks o...

Page 4: ...the move key entering instrument calibration mode Used together the two keys permit entering configuration mode BATTERY REPLACEMENT When replacing the battery please open the cover remove the plug and...

Page 5: ...tor which can be reset 1234567 is the general total which cannot be reset Measurement unit change See Fig 6 Press MOVE and RESET together and hold for more than 3 seconds Zone 7 on the display is the...

Page 6: ...Proper correction factor 1 000 20 75 18 96 1 000 1 094 1 094 1 2 3 4 5 Wait for the meter to go standby Reset the resettable total Press the MOVE key Keep it pressed until it shows similar to the rig...

Page 7: ...ut the actual value The volume that is displayed on the LCD is the Display Value not the Actual Value which may be slightly higher For example in the figure on the right the Display Value is 18 96 whi...

Page 8: ...ase your hand the transmission will be finished Notes When Using Cautions 1 For working condition please refer to the specification parameter list Temperature 10 C 60 C 2 Media Lubricant Oil OIL CONTR...

Page 9: ...contact your distributor for repair or replacement Inspect the nozzle for damage or obstructions and replace if damaged If the problem remains contact your distributor for repair or replacement Replac...

Page 10: ...caused by accident misuse or faulty installation 4 The product must be installed and maintained in compliance with the instructions EXPLODED AND PARTS LIST METER Part No 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2...

Page 11: ...1 1 Part No 4 10 4 11 4 12 4 13 4 14 4 15 4 16 4 17 4 18 Description Washer Seal Slip Pole O Ring O Ring Bushing O Ring O Ring Piston Sleeve Q ty 1 1 1 1 1 1 1 1 1 Wearing Parts E9 TECHNICAL DETAILS...

Page 12: ...Macnaught Americas 813 628 5506 info macnaughtusa com Read Manual Before Use...

Reviews: