Page 12 of 20
I
NDUSTRIAL
P
ULSE
C
AP
I
NTRODUCTION
The
Industrial Pulse Cap
comprises of 3 major components.
(See ‘exploded diagram’ on page 13)
1. INDUSTRIAL PULSER CAP
2. PCB (sensor board)
3. SECURE BASE PLATE
In order to access the PCB, or for the removal/replacement of the complete Pulser Module, the following
procedure applies.
Disassembly/Reassembly
**Please see page 13 for exploded diagram
1. Remove the 4 socket head cap screws holding the INDUSTRIAL PULSER CAP to the BASE PLATE. Take
care not to lose the gasket.
2. Lift the PULSER CAP to expose the terminal block for the connection/disconnection of the signal cables.
3. The PCB can be removed by loosening the two screws securing it to the BASE PLATE.
Note: It is not necessary to remove the PCB if the objective is to remove the complete base plate (see next
step)
4. To separate the BASE PLATE from the Flowmeter body, remove the stainless steel Circlip.
** Reassemble by reversing the above sequence.