Macnaught IM50 Instruction Manual Download Page 6

6

5. CALIBRATION

CALI 5

Note:  Provides calibration adjustment up to +/- 5% of
reading. You will need to calculate the percentage
adjustment you require. If the meter is reading over you will
need to enter a minus figure. If the meter is reading under
you will need to enter a plus figure.

51 CALIBRATION = CALI 51 ( adjust calib/- 5%)

b) Press the DISP button 3 times to reach “CALI 5”.

c) Press RESET “CALI 51” will appear.

d) Press and hold down RESET for 2 seconds ( program will
    appear and the first digit will flash).

e) Press RESET to change number.
   Press DISP to change the decimal point position, or go
    to the next number.
    Press the RESET button to set the negative value.

f) Press and hold down RESET until “program” disappears
    to accept setting.

g) Press RESET for five seconds to return the meter to the
    operating mode.

6. CONFIGURATION

CONF 6

6 CONFIGURATION = CONF 6 (configuration details)

b) Press the DISP button 4 times to reach “CONF 6”

c) Press RESET “MOD” plus model number  will appear.

d) Press RESET “REL” plus hardwear release number will
    appear.

e) Press RESET the screen will flash between “SOFT” and
    the softwear release no’s (at 2 second intervals).

f) Press RESET the screen will flash between “SEr” and the 6
   figure serial number (at 2 second intervals).

g) Press RESET “MAN” plus manufacturer number.

h) Press RESET the screen will flash between “CONFIG”
    and the configuration number (at 2 second intervals).

i) Press RESET for five seconds to return the meter to the
   operating mode.

7. DIAGNOSTICS

dIA 7

a) Press and hold down RESET for 5 seconds until  “MEtr 1”
    appears.

71 DIAGNOSTICS = dIA 7 (diagnostic mode)

b) Press the DISP  button 5 times to reach “dIA 7”.

c) Press RESET “ dIA 71”  will appear.

d) Press and hold down RESET for 2 seconds ( Program
    will appear then all the segments should be displayed).

e) Press the DISP button “diSP” ( to check that the display
    button is working properly).

f) Press the RESET  button “RESEt” ( to check that the reset
   button is  working properly).

g) 

Press and hold down RESET for 2 seconds ( Program

    will disappear (check the condition of the reed switch).

The condition of the reed switch can only be checked
when there is liquid flowing through the meter. The reed
switch should be reading between 50 - 80.

h) Press RESET for five seconds to return the meter to the
    operating mode.

d) Press RESET to select default time (5-20 seconds)

e) Press and hold down RESET until “program” disappears
    to accept setting.

f) Press RESET for five seconds to return the meter to the
    operating mode.

Step 1. Reset the batch reading to zero.

Step 2. Dispense at least 5 liters, using a constant flow rate,
            into a graduated calibrated container.

Step 3. Take the reading from the IM50.

Step 4. Calculate the % error as follows.

 % error = (( container volume - IM50 volume) / container volume) * 100

Step 5. Enter the % error into the meter as calculated, if the
            value is negative enter a negative number

a) Press and  hold down RESET for 5 seconds until  “totL2”
    appears.

a) Press and  hold down RESET for 5 seconds until  “totL2”
    appears.

c) Press and hold down RESET for 2 seconds ( program will
    appear)

b) Press the DISP button 2 times to reach “tiME 43”

a) Press and  hold down RESET for 5 seconds until  “totL2”
    appears.

43 TIME = tiME 43 (time to revert to default display)

Note: The display shows ( Hxx   rYY ) when fluid flows through
          the meter. YY is the sensitivity of the reed switch.

Summary of Contents for IM50

Page 1: ...ht Service Centre or Macnaught P L IMPORTANT INFORMATION The Macnaught IM50 Positive displacement flowmeter have incorporated the oval rotor principal into its design This has proven to be a highly re...

Page 2: ...Remove the 8 x philips head screws 1 from the meter cover 2 Remove the meter cover 2 and o ring 3 3 Remove both rotors 4 4 Clean and inspect all parts Replace any suspect worn or damaged components N...

Page 3: ...oint 25 change non resetable accumulative total units 26 change non reset accumulative total decimal point 22 change batch total decimal point 27 change K factor 31 change flowrate units 32 change flo...

Page 4: ...1 1 decimal place 27 K FACTOR kFac 27 normal setting is 112 00 pulses b Press RESET 7 times kFac 27 will appear c Press and hold down RESET for 2 seconds program will appear d To change the K factor...

Page 5: ...ds program will appear e Press RESET to select sleep setting no sleep sleep 5 f Press and hold down RESET until program disappears to accept setting f Press and hold down RESET until program disappear...

Page 6: ...AGNOSTICS dIA 7 diagnostic mode b Press the DISP button 5 times to reach dIA 7 c Press RESET dIA 71 will appear d Press and hold down RESET for 2 seconds Program will appear then all the segments shou...

Page 7: ...7 NOTES...

Page 8: ...re not manufactured by Macnaught and are supplied by Macnaught under a brand name other than Macnaught the Warranty period is the longer of 12 months from the date of purchase of the relevant product...

Reviews: