Product Specifications 

Troubleshooting Guide 

TROUBLE

CAUSE

REMEDY

Fluid w ill not flow  through the meter

a) Foreign matter blocking the rotors (6,7)

a) Dismantle the meter and clean the rotors (6,7)
     (Fit an in line strainer)

b) Strainer (4) is blocked

b) Clean strainer (4)

c) Damaged rotors (6,7)

c) Replace rotors (6,7) 

e) Connections over tightened

e) Re-adjust connections

Reduced flow  through the meter

Strainer partially blocked (4)

Clean strainer (4)

Meter reading inaccutate

a) Flow  rate is either too high or too low

a) Adjust flow  rate (refer to specifications) 

b) Excess w ear caused by incorrect 

b) Check meter body (1) register base (9) and rotors (6,7) for 

     installation

     w ear or damage.(Replace as required)

Fluid flow s but no reading on the meter

a) Drive gear loose (23)

a) Replace gear box cover assembly (16-23)

b) Rotor (6) drive gear damaged

b) Replace rotor (6)

c) Gearbox gears (13-16) damaged 

c) Replace damaged gears 

d) Register gears damaged

d) Replace register assembly

Fluid leaks into the register assembly

Damaged o'ring (20) or o'ring (24)

Replace gear box cover assembly (13-23) 
or o'ring (24)

Accuracy 

+/- 1” of Reading 

Type 

Oval Gear 

Flowrate 

3 - 80 Litre/min (0.8-21 US Gal/min) 

Maximum Pressure 

345kPa / 50psi / 3.45 Bar 

Suitable for use with 

Diesel, Kerosene, Petrol and Oils up to 1000cps.  

Reset-able Totalizer 

999.9 Lt or Gal 

Non-Reset-able Total 

999999 Lt or Gal 

Wetted Components 

Aluminium, Mild Steel, Brass 

 

Acetal, Viton, Polyetherimide Resin 

Port Threads 

1” Rp 

 

1” NPT 

 

1” BSP.F (G) 

Minimum Gravity Head 

550mm 

Summary of Contents for DM100-01

Page 1: ... you experience problems with the product refer to the Maintenance and Trouble Shooting sections of this manual If you require further assistance please contact your local Macnaught Distributor Authorised Macnaught Service Centre or Macnaught P L Macnaught recommends that as added protection to your equipment you install a Macnaught fuel filter assembly in line before the inlet of your DM Fuel Met...

Page 2: ...re at 90O to each other see fig 3 Check the rotor rotation by turning either of the rotors If the rotors are not in mesh correctly or do not move freely remove one of the rotors and replace it correctly at 900 to the other rotor Recheck the operation of the rotors 3 Insert o ring into the o ring groove on the register base 4 Carefully align the spring pins on the meter body to the spring pin holes...

Page 3: ...8 1 A O ring Viton BS150V 9 1 n a new meter required Register base 10 1 Dow el pins 11 4 Hex screw M6 X 20 12 4 Nut M6 13 1 1st Gear 14 1 2nd Gear 15 1 3rd Gear 16 1 4th Gear 17 1 ME035s Litre Output shaft 18 1 ME035US US Gal Circlip 19 1 Washer 20 1 A O ring Viton BS007V 21 1 Gear box cover 22 1 Bush 23 1 Gear 24 1 A O ring Viton BS032V 25 2 Screw M4 X 16 26 1 Register assembly 27 1 Facia plate 2...

Page 4: ...rotors 6 7 for installation w ear or damage Replace as required Fluid flow s but no reading on the meter a Drive gear loose 23 a Replace gear box cover assembly 16 23 b Rotor 6 drive gear damaged b Replace rotor 6 c Gearbox gears 13 16 damaged c Replace damaged gears d Register gears damaged d Replace register assembly Fluid leaks into the register assembly Damaged o ring 20 or o ring 24 Replace g...

Reviews: