Macnaught DM100-01 Instruction Manual Download Page 2

 

ME042 Issue 15 © 2014 

 

Register rotation 

1) Unscrew the 4 screws holding the register assembly  

2) Carefully lift off the complete register assembly from the 
register base  

3) Rotate the register assembly to the desired position.  

4) Carefully re-fit the register assembly to the meter body.     

 

Do  not  force  the  register  assembly  when  re-fitting  to 
the  register  base.  Ensure  that  both  the  register  drive 
gear and meter drive gear are properly engaged before 
replacing the register screws, or damage may occur.     

5) Replace the 4 register screws.

 

Meter disassembly 

1)  Ensure  that  the  fluid  supply  to  the  meter  is 
disconnected, and the line pressure is released 
before disassembly. 

2) Unscrew the 4 screws holding the register  
assembly. 

3) Carefully lift off the complete register assembly from the 
register base  

4)  Remove  the  4  gear  box  cover  screws  and  carefully 
remove  the  gear  box  cover  assembly,  o’ring  and  gears 
from the gear box. 

NOTE: The gear on the gear box cover  
assembly  should  not  be  removed.  If  there  is  any  wear  or 
damage the complete gear box cover assembly should be 
replaced. 

5) Remove the 4 hex bolts holding the register base to the 
meter body remove the meter body o’ring and both  rotors 

Check all components for wear or damage and replace as 
required. 

Meter reassembly 

1) Clean all components before reassembly. 

NOTE: 

The rotor with the drive pinion must be fitted to the side of 
the  meter  body,  which  has  D/Gear  marked  on  the  meter 
body, (see fig 3). 

  

2)  Replace  the  rotors  so  as  they  are  at  90

O

 

to  each  other, 

(see fig 3). Check the rotor rotation by turning either of the  
rotors.  If  the  rotors  are  not  in  mesh  correctly  or  do  not 
move  freely  remove  one  of  the  rotors  and  replace  it 
correctly at 90

0

 to the other rotor. Recheck the operation of 

the rotors.

   

3) Insert o’ring into the o’ring groove on the register base  

4) Carefully align the spring pins on the meter body  to the 
spring pin holes on the register base 

 

D/GEAR 

(fig 3) 

5) Replace the 4 hex screws and nuts and tighten firmly. 

6)  Insert  gear  marked  L1(Litre)  or  Q1  (Quart)  onto  the 
shaft located in the gear box. 

7) Place the gear marked L2 (Litre) or Q2 (Quart) on top 
of gear 1. The hole in gear 2 should be positioned to align 
with the output shaft hole in the gear box.  

8) Place the gear marked L3 (Litre) or Q3 (Quart) onto the 
same shaft  as gear 1. 

9) Insert the gearbox cover o’ring into the o’ring 
groove on the gear box cover  

10) Fit the gear box cover assembly by carefully inserting 
the output shaft through gear 2  and into the output shaft 
hole in the gear box.   

11) Fit the 4 gear box cover screws  and tighten securely. 

12) Rotate the register assembly to the desired position. 

13)  Carefully  re-fit  the  register  assembly    to  the  meter 
body. Fit 4 screws and tighten firmly. 

14) Press the reset button to reset the batch total to zero. 

15) Test the meter by turning the rotors with a finger or by 
applying  low  air  pressure.  (No  more  than  a  good  breath) 
to the inlet port of the meter. This will confirm the meter is 
operating  correctly  and  that  the  number  wheels  are 
ascending.   

DM150 Meter and Filter assembly 

FLOW 

(fig 4) 

 CAUTION 

Note: 
        Order DM150-01 for Meter and Filter assembly complete 

Note: 
        Order HA1s for filter assembly only 

Summary of Contents for DM100-01

Page 1: ... you experience problems with the product refer to the Maintenance and Trouble Shooting sections of this manual If you require further assistance please contact your local Macnaught Distributor Authorised Macnaught Service Centre or Macnaught P L Macnaught recommends that as added protection to your equipment you install a Macnaught fuel filter assembly in line before the inlet of your DM Fuel Met...

Page 2: ...re at 90O to each other see fig 3 Check the rotor rotation by turning either of the rotors If the rotors are not in mesh correctly or do not move freely remove one of the rotors and replace it correctly at 900 to the other rotor Recheck the operation of the rotors 3 Insert o ring into the o ring groove on the register base 4 Carefully align the spring pins on the meter body to the spring pin holes...

Page 3: ...8 1 A O ring Viton BS150V 9 1 n a new meter required Register base 10 1 Dow el pins 11 4 Hex screw M6 X 20 12 4 Nut M6 13 1 1st Gear 14 1 2nd Gear 15 1 3rd Gear 16 1 4th Gear 17 1 ME035s Litre Output shaft 18 1 ME035US US Gal Circlip 19 1 Washer 20 1 A O ring Viton BS007V 21 1 Gear box cover 22 1 Bush 23 1 Gear 24 1 A O ring Viton BS032V 25 2 Screw M4 X 16 26 1 Register assembly 27 1 Facia plate 2...

Page 4: ...rotors 6 7 for installation w ear or damage Replace as required Fluid flow s but no reading on the meter a Drive gear loose 23 a Replace gear box cover assembly 16 23 b Rotor 6 drive gear damaged b Replace rotor 6 c Gearbox gears 13 16 damaged c Replace damaged gears d Register gears damaged d Replace register assembly Fluid leaks into the register assembly Damaged o ring 20 or o ring 24 Replace g...

Reviews: