Mackie UP4061 Instruction Manual Download Page 4

UP4000 – 4

FRONT PANEL FEATURES

LOW EQ

 is a shelving filter that provides 12 dB

of boost and cut below 100Hz.

HIGH EQ

 is a shelving filter that provides 12 dB

of boost and cut above 10kHz.

VOLUME

 is a master volume control used to

adjust the overall volume of the signal at the

POWER OUTPUTS

.

Use the 

POWER

 switch to turn the UP4000

Series on and off.

The 

STD-BY

 indicator lights when the amplifier is

in standby mode.

Note:

 Standby mode is disabled by default. An

internal jumper (J1 on the input board) must be
changed to enable standby mode. See "Internal
Settings" on page 8.

The 

OVERLOAD

 indicator lights when the

amplifier is operating in overload, a condition
generally caused by a problem on the speaker line.
When the amplifier is switched on, the 

OVERLOAD

light comes on for a few seconds. This is normal
and does not indicate a problem.

The 

SIGNAL

 indicator lights when a signal is

present at the 

POWER OUTPUTS

.

The 

PEAK

 indicator lights when the output signal

is approaching clipping.

The 

ON

 indicator lights when the UP4000 is

turned on and ready for operation.

REAR PANEL FEATURES

POWER INPUT

 provides a means to connect an

external 24 VDC power supply or battery as an
alternative or backup power source. The UP4000
Series seamlessly switches to the backup supply if
there's an AC power loss. When both AC power
and 24 VDC power are connected, the DC power is
switched off.

Note:

 The unit is not equipped with battery charging

capability.

The 

D.C. FUSE

 protects the DC power input to

the amplifier circuit. Replace with the same type
fuse only.

POWER OUTPUTS

 

are screw-terminal

connections for connecting speakers to the 4-ohm,
25V, 50V, 70V, or 100V outputs.

WARNING:

 To prevent the risk of electric shock,

never touch the bare wires coming from the output
terminals of the amplifier when it is switched on.
When all connections have been made, insulate the
output terminals of the amplifier using the
protective cover provided.

Constant-Impedance Output

The total impedance of the speakers and cable
connected to the "4

" constant-impedance output

should be 4 ohms. Connect the "4

" terminal to

the "+" (HIGH) speaker terminal, and the "0"
terminal to the "–" (LOW) speaker terminal.

Constant-Voltage Output

In a constant-voltage system, each speaker must
be equipped with a line transformer having an
input voltage equal to that of the line (e.g., 25V,
50V, 70V, or 100V). Typically, these line trans-
formers have selectable power taps (i.e., 2.5W,
5W, 10W) for connecting to the constant-voltage
line. 

CAUTION:

 The sum of the wattage values

of the speakers must not exceed the output
power of the amplifier.

POWER

LOW

EQ

HIGH

VOLUME

PEAK

OVERLOAD SIGNAL

ON

UP 4161 - P.A. AMPLIFIER

STD-BY

0

10

8

2

1

3

4

5

6

7

9

8

4

2

0

2

4

8

-10

+10

6

6

8

4

2

0

2

4

8

-10

+10

6

6

Summary of Contents for UP4061

Page 1: ...NDING COPYRIGHT 1999 SERIAL NUMBER MANUFACTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RE...

Page 2: ...other servicing should be referred to the Mackie Service Department 13 To prevent electric shock do not use this polarized plug with an extension cord receptacle or other outlet unless the blades can...

Page 3: ...put features a parallel output and 0 dB 20 dB sensitivity switch Output modes include 4 constant impedance and 25V 50V 70V and 100V constant voltage The smart output stage is fully protected against p...

Page 4: ...p supply if there s an AC power loss When both AC power and 24 VDC power are connected the DC power is switched off Note The unit is not equipped with battery charging capability The D C FUSE protects...

Page 5: ...e Connect the supplied AC linecord to the IEC AC Socket The AC line fuse is contained in the socket behind the cover located at the bottom of the socket Replace only with same type fuse The VOLTAGE SE...

Page 6: ...TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE M ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SH...

Page 7: ...ors are screw terminals Use 16 or 18 gauge wire for connecting the amplifier outputs to the speakers Strip the wire back about 1 2 inch loosen the screw enough to loop the wire around the shaft of the...

Page 8: ...amplifier to allow adequate cooling for the heatsink Leave at least one rack space above and below the UP4000 and at least 6 inches behind the chassis to allow proper ventilation If the amplifier sho...

Page 9: ...Series is shipped with the Standby Mode disabled Move jumper J1 on the input board to enable the Standby Mode see instructions on page 8 OVERL Connect an LED or relay between this terminal and the GND...

Page 10: ...ts peak 10ms Frequency Response 50Hz to 15kHz 3 dB Distortion THD 1 1kHz nominal power Signal To Noise Ratio 80 dB below nominal power Audio Inputs Balanced Line Input One active balanced barrier stri...

Page 11: ...l packaging Original packaging helps to minimize the possibility of shipping damage 3 Include a legible note stating your name return shipping address no P O boxes daytime phone number Return Authoriz...

Page 12: ...888 337 7404 FAX 425 487 4337 industrial mackie com UK 44 1268 571 212 FAX 44 1268 570 809 industrial rcf uk com ITALY 39 0522 354 111 FAX 39 0522 926 208 industrial rcf it FRANCE 33 3 8546 9160 FAX...

Reviews: