Mackie UP4061 Instruction Manual Download Page 1

POWER

LOW

EQ

HIGH

VOLUME

PEAK

OVERLOAD SIGNAL

ON

UP 4161 - P.A. AMPLIFIER

STD-BY

0

10

8

2

1

3

4

5

6

7

9

8

4

2

0

2

4

8

-10

+10

6

6

8

4

2

0

2

4

8

-10

+10

6

6

+

D.C. FUSE

115

0

50V

70V

100V

POWER OUTPUTS

0

25V

POWER INPUT

24V D.C.

COMMANDS

VOLTAGE

SELECTOR

POWER OUTPUTS

LINE

     50/60 Hz-115/230V

-

4

INPUT

0dB

20dB

ON

OFF

PRIORITY

GND

UNBALANCED IN

GND

H.P.

FILTER

BALANCED

IN

L.P.

STAND

BY

SENSITIVITY

GND

PARALLEL OUT

OVERL.

300mA.

max

CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE INDUSTRIAL • MADE IN ITALY • PATENTS PENDING • COPYRIGHT ©1999

SERIAL NUMBER

MANUFACTURING DATE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE

UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE

WARNING: 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. 
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

CAUTION

AVIS:

 

RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR

 THE FOLLOWING ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE 

UP4000 Series

Power Amplifier

UP4061 • UP4121 • UP4161

Instruction Manual

Summary of Contents for UP4061

Page 1: ...NDING COPYRIGHT 1999 SERIAL NUMBER MANUFACTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RE...

Page 2: ...other servicing should be referred to the Mackie Service Department 13 To prevent electric shock do not use this polarized plug with an extension cord receptacle or other outlet unless the blades can...

Page 3: ...put features a parallel output and 0 dB 20 dB sensitivity switch Output modes include 4 constant impedance and 25V 50V 70V and 100V constant voltage The smart output stage is fully protected against p...

Page 4: ...p supply if there s an AC power loss When both AC power and 24 VDC power are connected the DC power is switched off Note The unit is not equipped with battery charging capability The D C FUSE protects...

Page 5: ...e Connect the supplied AC linecord to the IEC AC Socket The AC line fuse is contained in the socket behind the cover located at the bottom of the socket Replace only with same type fuse The VOLTAGE SE...

Page 6: ...TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE M ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SH...

Page 7: ...ors are screw terminals Use 16 or 18 gauge wire for connecting the amplifier outputs to the speakers Strip the wire back about 1 2 inch loosen the screw enough to loop the wire around the shaft of the...

Page 8: ...amplifier to allow adequate cooling for the heatsink Leave at least one rack space above and below the UP4000 and at least 6 inches behind the chassis to allow proper ventilation If the amplifier sho...

Page 9: ...Series is shipped with the Standby Mode disabled Move jumper J1 on the input board to enable the Standby Mode see instructions on page 8 OVERL Connect an LED or relay between this terminal and the GND...

Page 10: ...ts peak 10ms Frequency Response 50Hz to 15kHz 3 dB Distortion THD 1 1kHz nominal power Signal To Noise Ratio 80 dB below nominal power Audio Inputs Balanced Line Input One active balanced barrier stri...

Page 11: ...l packaging Original packaging helps to minimize the possibility of shipping damage 3 Include a legible note stating your name return shipping address no P O boxes daytime phone number Return Authoriz...

Page 12: ...888 337 7404 FAX 425 487 4337 industrial mackie com UK 44 1268 571 212 FAX 44 1268 570 809 industrial rcf uk com ITALY 39 0522 354 111 FAX 39 0522 926 208 industrial rcf it FRANCE 33 3 8546 9160 FAX...

Reviews: