Mackie TH-12A Features 

 

REAR PANEL DESCRIPTION

3. LEVEL 

The LEVEL control adjusts the overall signal level at 

the input to the built-in power amplifiers. It ranges from 
Off ( ) to MAX (maximum gain), with unity gain at the 
center position (12 o’clock). 

•   The TH-12A is designed to operate with a +4   

    dBu signal when the LEVEL control is at the U  
    (center) position.

•   The TH-12A can accept up to a +20 dBu signal  

    by  turning down the LEVEL control accordingly.  
    Turning the LEVEL past unity will provide enough  
    gain to connect a microphone directly.

•   NEVER connect the output of an amplifier directly  

    to the input of the TH-12A. This could damage the  
    active input circuitry of the loudspeaker.

This is where you connect AC power and your 

signal to the loudspeaker and make adjustments to 
the frequency response of the speaker to match the 
loudspeaker’s location and your room’s environment.

1. INPUT

This is a female XLR-type connector that accepts a 

balanced mic or line-level signal from a mixing console 
or other signal source. For small gigs, simply connect a 
microphone directly and adjust the LEVEL control [3] 
accordingly.

2. THRU 

This is a male XLR-type connector that produces 

exactly the same signal that is connected to the input 
jack. Use it to daisy-chain several TH-12As together off 
the same signal source.

OL

LEVEL

U

+15

-15

U

+15

-15

U

+15

-15

600

8k

100

MAX

O

O

U

FREQ

HIGH

12kHz

LOW

80Hz

MID

THRU

EQ

CONTOUR EQ

INPUT

ON

POWER

OFF
ON

O

1

2

3

4

5

7

6

8

9

10

11

Summary of Contents for TH-12A

Page 1: ...OWNER S MANUAL 2 Way 12 Powered Loudspeaker TH 12A...

Page 2: ...r an experienced radio TV technician for help CAUTION Changes or modifications to this device not expressly approved by LOUD Technologies Inc could void the user s authority to operate the equipment u...

Page 3: ...pport return authorization etc Don t forget to visit our website at www mackie com for more information about this and other Mackie products Loudspeaker 1 Loudspeaker 2 Please write the serial number...

Page 4: ...f the volume from the speakers gets really loud really fast try turning down the LEVEL control on the TH 12A a bit If the speakers don t get loud enough turn up the LEVEL control to achieve a good bal...

Page 5: ...Hz MID THRU EQ CONTOUR EQ INPUT ON POWER OFF ON O OL LEVEL U 15 15 U 15 15 U 15 15 600 8k 100 MAX O O U FREQ HIGH 12kHz LOW 80Hz MID THRU EQ CONTOUR EQ INPUT ON POWER OFF ON O TAPE IN ST RETURN MAIN O...

Page 6: ...L R L R L R L R MON SEND FX PRESETS MON MAIN 4 3 3 2 2 1 5 6 7 8 9 10 11 12 MAIN METERS BREAK TAPE LEVEL USB THRU 1 R L INPUT LEVEL USB MUTE MUTE MUTE MUTE MUTE MUTE MUTE MUTE MUTE 48V TH 12A TH 12A T...

Page 7: ...he inputs of two powered subwoofers The high pass line level outputs of the subwoofers feed the inputs of the Mackie TH 12A loudspeakers MON MAIN 4 3 2 1 5 6 7 8 9 10 11 12 Left and Right Main Powered...

Page 8: ...ge the active input circuitry of the loudspeaker This is where you connect AC power and your signal to the loudspeaker and make adjustments to the frequency response of the speaker to match the loudsp...

Page 9: ...monics for many instruments 7 MID FREQ This knob ranges from 100 Hz to 8 kHz and determines the center frequency for the MID EQ filter This allows you to zero in on the precise narrow band of frequenc...

Page 10: ...ction mechanisms designed into the TH 12A to safeguard the loudspeakers and amplifiers from inadvertent damage CAUTION The protection circuits are designed to protect the loudspeakers under reasonable...

Page 11: ...back into the IEC socket If two fuses blow in a row then something is very wrong Try a different outlet in a totally different location If fuses continue to blow see the Repair section on the next pag...

Page 12: ...thorized service center To locate your nearest service center call our Tech Support department at 1 800 898 3211 Monday Friday during normal business hours Pacific Time to explain the problem Tech Sup...

Page 13: ...m of the cabinet Be sure the pole is capable of supporting the weight of the TH 12A Acoustic Performance Frequency Range 10 dB 57 Hz 20 kHz Frequency Response 3 dB 70 Hz 18 5 kHz Horizontal Coverage A...

Page 14: ...m 22 8 in 579 mm 20 6 in 522 mm 12 4 in 314 mm 14 5 in 367 mm 6 0 in 152 mm 6 3 in 160 mm 14 1 in 357 mm WEIGHT 25 5 lb 11 6 kg CONTOUR EQ 5aT dT Rh 7i RcPeT ATb_ bT S1 B E TH 12A Frequency Response T...

Page 15: ...istered trademarks of LOUD Technologies Inc All other brand names mentioned are trademarks or registered trademarks of their respective holders and are hereby acknowledged 2011 LOUD Technologies Inc A...

Page 16: ...visit www mackie com warranty to find contact information for your local distributor and information on any warranty coverage provided by the distributor in your local market LOUD warrants to Customer...

Page 17: ...Road NE Woodinville WA 98072 USA United States and Canada 800 898 3211 Europe Asia Central and South America 425 487 4333 Middle East and Africa 31 20 654 4000 Fax 425 487 4337 www mackie com E mail s...

Reviews: