background image

12

Noise/Hum

•  Check the signal cable between the mixer and  

    the loudspeaker. Make sure all connections are  
    secure. These problems usually produce crackling  
    noises or hum. 

•  If you are using two or more TH-12A powered  

    loudspeakers, try plugging them all into the same  
    AC outlet panel or outlet strip. The purpose for  
    this is to connect them all to the same earth    
    ground point and reduce the possibility of creating  
    a ground loop. 

•  If connecting an unbalanced output to the TH-12A  

    balanced input, make sure the shield is connected  
    to the unbalanced ground and to pin 1 of the XLR.

Repair

For warranty service, refer to the warranty 

information on page 16. 

Non-warranty service for Mackie products is 

available at a factory-authorized service center. To 
locate your nearest service center, call our Tech 
Support department at 1-800-898-3211, Monday-Friday, 
during normal business hours, Pacific Time, to explain 
the problem. Tech Support will tell you where the 
nearest factory-authorized service center is located in 
your area.

Appendix B: Connections 

XLR Connectors

XLR connectors are used to make balanced input 

and through connections to the TH-12A. They are wired 
as follows, according to standards specified by the AES 
(Audio Engineering Society). 
 

XLR

  

Hot (+) Pin 2 

 

Cold (–)Pin 3 

 

Shield (Ground) Pin 1 

Balanced XLR Connectors

2

2

3

1

1

SHIELD

COLD

HOT

SHIELD

COLD

HOT

3

SHIELD

COLD

HOT

3

2

1

 

 

 

 

Need help with your new loudspeaker? 

 

•  Visit www.mackie.com and click Support to find: FAQs, manuals, addendums, and other documents. 
  
•  Email us at: [email protected]
 
•  Telephone 1-800-898-3211 to speak with one of our splendid technical support chaps (Monday  

 

    through Friday, normal business hours, PST).

Summary of Contents for TH-12A

Page 1: ...OWNER S MANUAL 2 Way 12 Powered Loudspeaker TH 12A...

Page 2: ...r an experienced radio TV technician for help CAUTION Changes or modifications to this device not expressly approved by LOUD Technologies Inc could void the user s authority to operate the equipment u...

Page 3: ...pport return authorization etc Don t forget to visit our website at www mackie com for more information about this and other Mackie products Loudspeaker 1 Loudspeaker 2 Please write the serial number...

Page 4: ...f the volume from the speakers gets really loud really fast try turning down the LEVEL control on the TH 12A a bit If the speakers don t get loud enough turn up the LEVEL control to achieve a good bal...

Page 5: ...Hz MID THRU EQ CONTOUR EQ INPUT ON POWER OFF ON O OL LEVEL U 15 15 U 15 15 U 15 15 600 8k 100 MAX O O U FREQ HIGH 12kHz LOW 80Hz MID THRU EQ CONTOUR EQ INPUT ON POWER OFF ON O TAPE IN ST RETURN MAIN O...

Page 6: ...L R L R L R L R MON SEND FX PRESETS MON MAIN 4 3 3 2 2 1 5 6 7 8 9 10 11 12 MAIN METERS BREAK TAPE LEVEL USB THRU 1 R L INPUT LEVEL USB MUTE MUTE MUTE MUTE MUTE MUTE MUTE MUTE MUTE 48V TH 12A TH 12A T...

Page 7: ...he inputs of two powered subwoofers The high pass line level outputs of the subwoofers feed the inputs of the Mackie TH 12A loudspeakers MON MAIN 4 3 2 1 5 6 7 8 9 10 11 12 Left and Right Main Powered...

Page 8: ...ge the active input circuitry of the loudspeaker This is where you connect AC power and your signal to the loudspeaker and make adjustments to the frequency response of the speaker to match the loudsp...

Page 9: ...monics for many instruments 7 MID FREQ This knob ranges from 100 Hz to 8 kHz and determines the center frequency for the MID EQ filter This allows you to zero in on the precise narrow band of frequenc...

Page 10: ...ction mechanisms designed into the TH 12A to safeguard the loudspeakers and amplifiers from inadvertent damage CAUTION The protection circuits are designed to protect the loudspeakers under reasonable...

Page 11: ...back into the IEC socket If two fuses blow in a row then something is very wrong Try a different outlet in a totally different location If fuses continue to blow see the Repair section on the next pag...

Page 12: ...thorized service center To locate your nearest service center call our Tech Support department at 1 800 898 3211 Monday Friday during normal business hours Pacific Time to explain the problem Tech Sup...

Page 13: ...m of the cabinet Be sure the pole is capable of supporting the weight of the TH 12A Acoustic Performance Frequency Range 10 dB 57 Hz 20 kHz Frequency Response 3 dB 70 Hz 18 5 kHz Horizontal Coverage A...

Page 14: ...m 22 8 in 579 mm 20 6 in 522 mm 12 4 in 314 mm 14 5 in 367 mm 6 0 in 152 mm 6 3 in 160 mm 14 1 in 357 mm WEIGHT 25 5 lb 11 6 kg CONTOUR EQ 5aT dT Rh 7i RcPeT ATb_ bT S1 B E TH 12A Frequency Response T...

Page 15: ...istered trademarks of LOUD Technologies Inc All other brand names mentioned are trademarks or registered trademarks of their respective holders and are hereby acknowledged 2011 LOUD Technologies Inc A...

Page 16: ...visit www mackie com warranty to find contact information for your local distributor and information on any warranty coverage provided by the distributor in your local market LOUD warrants to Customer...

Page 17: ...Road NE Woodinville WA 98072 USA United States and Canada 800 898 3211 Europe Asia Central and South America 425 487 4333 Middle East and Africa 31 20 654 4000 Fax 425 487 4337 www mackie com E mail s...

Reviews: