background image

SP400C – 7

SP400C Frequency Response vs. Impedance

Frequency (Hz)

SPL, 1W/1m (dB)

Impedance (ohms)

20

60

70

80

90

100

100

1000

3160

100

1000

10000

20000

Frequency (Hz)

Vert BW

Horz BW

–6 dB Beamwidth (degrees)

20

60

120

180

240

300

360

100

1000

10000

20000

SP400C Beamwidth vs. Frequency

Waveguide Design

Horizontal Coverage:

110º 1 kHz to 6 kHz averaged

Vertical Coverage:

110º 1 kHz to 6 kHz averaged

Type:

Exponential

Mouth Size:

3.75" x 3.75" (95 mm x 95 mm)

Throat Size:

1.0" (25 mm)

Physical

Contruction Features

Basic Design:

2-way, front loaded

Bezel Material:

UL94V-0 rated material

Rear Enclosure Material:

Steel

Grille:

Perforated metal with weather-

resistant coating

Safety Features

Rear-hanging Ring:

Safety loop located at rear of

enclosure for attachment of load

bearing safety strap

11.8 in.

(300 mm)

9.5 in.

(241 mm)

10.8 in.

(274 mm)

5.6 in.

(142 mm)

6.6 in.

(168 mm)

Safety Agency Rating

UL1480:

General Signaling Fire Standard

UL2043:

Fire Test for Heat and Visible Smoke

Release for Discrete Products and

Their Accessories Installed in Air-

handling Spaces

Inputs/Outputs:

Removable locking connector with

screw-down terminals

2 input terminals and 2 loop-thru

terminals.

Dimensions

Diameter x Height:

11.8" x 6.6" (300 mm x 168 mm)

Front of Ceiling Tile to Back of Back Can:

5.6" (142 mm)

Cutout Size:

10.8" (274 mm)

Net Weight:

7.9 lbs. (3.6 kg)

Included Accessories:

Grille, Support Rails, C-Ring,

Removable Locking Connector, Cut-

out Template, Paint Shield

Summary of Contents for SP400C

Page 1: ...SP400C 2 Way Ceiling Monitor Sound Palette Instruction Manual 3 7 7 5 15 30 70v 100v HIGH PASS FULL RANGE FULL RANGE 16 OHMS 7 5 15 30...

Page 2: ...d Health Administration OSHA has established the maximum sound pressure levels that can be with stood without causing damage which are shown in the table below According to the OSHA regulations any ex...

Page 3: ...V 100V distribution systems or low impedance operation An easily accessible rotary switch on the front panel selects the appropriate tap from 3 7 watts to 30 watts A second switch allows you to select...

Page 4: ...tion in level as you move around the area The downside of higher density coverage of course is that more speakers are required for a given area Installation Note Observe all local and national codes w...

Page 5: ...TIGHTEN 1 2 3 4 LO O P THRU LO O P THRU IN IN B2 Open the terminal cover plate 7 on the back of the SP400C Use a threaded conduit set screw coupler not supplied For 1 2 conduit use Thomas Betts Steel...

Page 6: ...ke sure all the taps in the system add up to less than the rated power of the amplifier driving them As a general rule you should provide at least 10 headroom to account for insertion losses i e wirin...

Page 7: ...rated metal with weather resistant coating Safety Features Rear hanging Ring Safety loop located at rear of enclosure for attachment of load bearing safety strap 11 8 in 300 mm 9 5 in 241 mm 10 8 in 2...

Page 8: ...instructions 1 Call Mackie Designs Tech Support at 1 888 337 7404 7 am to 5 pm PST Monday Friday to verify the problem and obtain a Return Authorization RA Number Be sure to have the serial number of...

Reviews: