background image

SP400C – 5

speaker connector 

(8)

 to the 4-pin terminal.

Tighten the strain relief screws to secure the
speaker cable or flexible conduit. Close the
terminal cover plate 

(7)

 and tighten the locking

screw 

(7a)

 firmly.

B. 

Installation with Rigid Conduit 

1

B1.Remove the two screws holding the strain relief

(9)

 onto the rear cover and remove the strain

relief assembly.

Support Rails

C-Ring

Ceiling Tile

T-Channels

Flexible
Conduit

A3.Insert the speaker into the hole all the way, so

the front baffle rim is flush against the ceiling.

3.7

7.5

15

30

70v

100v

HIGH
PASS

FULL

RANGE

FULL

RANGE

(16 OHMS)

7.5

15

30

A4.Turn the four attachment

screws 

(5)

 clockwise until

tight to secure the
mounting tabs over the
C-ring. 

DO NOT

OVERTIGHTEN.

1

2

3

4

+

LOOP

THRU

LOOP

THRU

IN

IN

+

B2.Open the terminal cover plate 

(7)

 on the back of

the SP400C. Use a threaded conduit set-screw
coupler (not supplied: For 1/2" conduit, use
Thomas&Betts Steel City model TC221-SC or UL
listed equivalent) and insert into the opening
exposed by removing the strain relief assembly.

B3.Fasten the coupler to the cover using the nut

supplied with the coupler.

1

2

3

4

+

LOOP

THRU

LOOP

THRU

IN

IN

+

Threaded Conduit 
Set-Screw Coupler

(Thomas&Betts

Steel City

TC221-SC

or equivalent)

B4. Insert the speaker into the
hole all the way, so the front
baffle rim is flush against the
ceiling.

B5. Turn the four attachment
screws 

(5)

 clockwise until

tight to secure the mounting
tabs over the C-ring. 

DO NOT

OVERTIGHTEN.

This method can be used with 1/2"

flexible conduit by substituting a
Thomas&Betts Steel City model
XC241 flexible conduit fitting (or UL
listed equivalent).

Summary of Contents for SP400C

Page 1: ...SP400C 2 Way Ceiling Monitor Sound Palette Instruction Manual 3 7 7 5 15 30 70v 100v HIGH PASS FULL RANGE FULL RANGE 16 OHMS 7 5 15 30...

Page 2: ...d Health Administration OSHA has established the maximum sound pressure levels that can be with stood without causing damage which are shown in the table below According to the OSHA regulations any ex...

Page 3: ...V 100V distribution systems or low impedance operation An easily accessible rotary switch on the front panel selects the appropriate tap from 3 7 watts to 30 watts A second switch allows you to select...

Page 4: ...tion in level as you move around the area The downside of higher density coverage of course is that more speakers are required for a given area Installation Note Observe all local and national codes w...

Page 5: ...TIGHTEN 1 2 3 4 LO O P THRU LO O P THRU IN IN B2 Open the terminal cover plate 7 on the back of the SP400C Use a threaded conduit set screw coupler not supplied For 1 2 conduit use Thomas Betts Steel...

Page 6: ...ke sure all the taps in the system add up to less than the rated power of the amplifier driving them As a general rule you should provide at least 10 headroom to account for insertion losses i e wirin...

Page 7: ...rated metal with weather resistant coating Safety Features Rear hanging Ring Safety loop located at rear of enclosure for attachment of load bearing safety strap 11 8 in 300 mm 9 5 in 241 mm 10 8 in 2...

Page 8: ...instructions 1 Call Mackie Designs Tech Support at 1 888 337 7404 7 am to 5 pm PST Monday Friday to verify the problem and obtain a Return Authorization RA Number Be sure to have the serial number of...

Reviews: