background image

11

• Simple ports or ducts must have sufficient

surface area to prevent the velocity of the
air within them from exceeding 5% of the
speed of sound, which keeps the vent from
becoming audible (breathing and wheezing
sounds) at high signal levels.

• This requirement for sufficient surface area

creates a design problem when using ports —
finding enough space in the enclosure for
them to fit.

The passive radiator replaces the port found

on most speaker systems. It offers several ad-
vantages to simple porting:
• One primary advantage of a passive

radiator is that it can reproduce low
frequencies with lower distortion and at a
higher sound pressure level (SPL) than a
simple port or duct.

• Our unique passive radiator design uses a

flat diaphragm providing exceptional
stiffness to the radiating surface.

• The elliptical shape of the passive radiator

takes up nearly the entire surface area
available on the rear of the enclosure,
allowing the passive radiator to move more
air than a port.

 Mains Input

Connect the power cord to this IEC socket, and

plug the other end into your AC outlet.
• When the 

POWER MODE

 

 switch is in

the 

ON

 position (and the mute 

 switch

is in the OUT position), applying AC power
activates the muting circuit for about four
seconds while the power supply and
internal circuitry stabilize, then the HR624
unmutes and is ready to go.

 Passive Radiator

When you mount a loudspeaker in a box,

there are two things that you can do with the
radiation from the rear of the cone: use it to
enhance the low-frequency performance of the
speaker system (bass reflex system) or soak it
up (acoustic suspension system).
• A bass reflex system uses the rear radiation

to extend the low-frequency response. Most
systems provide holes (ports) in the front
or back of the cabinet to release the rear
wave. Sometimes the holes have tubes
(ducts) in them. The dimensions of the
holes and the volume of the cabinet work
with the characteristics of the woofer to
produce low-frequency extension. These
systems are characterized by good low-
frequency performance down to the –3 dB
frequency set by the design. Below this
frequency, the frequency response falls at
24 dB/octave or more.

The HR624 is a bass reflex 6th-order system.

Rather than use ports, the vent takes the form
of a passive radiator, a mass-loaded flat piston
coupled to the air trapped within the enclo-
sure. You can’t see the passive radiator because
it is located at the rear of the cabinet, behind
the power amplifier assembly.

Tweeter

Woofer

Passive Radiator

Summary of Contents for HR624

Page 1: ...HR624 HIGH RESOLUTION ACTIVE STUDIO MONITOR OWNER S MANUAL...

Page 2: ...ert 15 Grounding or Polarization Precautions should be taken so that the grounding or polarization means of this Mackie product is not defeated 16 Power Protection Unplug this Mackie product during li...

Page 3: ...accurate and versatile loaded with unique controls that allow you to fine tune the sound to match your individual environment precisely You re gonna love these What are they The Advantages TheHR624Stu...

Page 4: ...ntil you read about them later on in this manual so you really know what they do For now just leave them at the factory default set exponential waveguide which results in wide controlled dispersion of...

Page 5: ...0Hz LOW CUT 49Hz NORMAL B C RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING TOREDUCETHERISKOFFIREORELECTRICSHOCK DONOT EXPOSETHISEQUIPMENTTORAINORMOISTURE DONOTREMOVECOVER NOUSERSERVICEABLEPARTSINSIDE REFE...

Page 6: ...est bass response in a room that s optimized for bass reproduction A lot of factors can conspire to thwart the HR624s extended low frequency including room shape room volume and acoustical treatment T...

Page 7: ...channel material should have the option to use pm3 THX pm3 Certifi cation is ideal for DVD mastering sweetening and mixing and is also perfect for facilities do ing work in broadcast music or multi me...

Page 8: ...use the HR624s free standing away from walls and corners whole space set the ACOUSTIC SPACE switch to the C position NORMAL This is where you connect your signal to the monitor and make adjustments t...

Page 9: ...enhancing low frequency output use the 49Hz NORMAL position The LOW FREQ switch affects the low frequency content of your mix Remember how things work in reverse so removing the deep bass content on...

Page 10: ...r amplifiers are live and operate normally The front panel mute switch must also be OUT When it s in the AUTO ON position the amplifiers turn on and off depending on the presence or absence of an inpu...

Page 11: ...e OUT position applying AC power activates the muting circuit for about four seconds while the power supply and internal circuitry stabilize then the HR624 unmutes and is ready to go Passive Radiator...

Page 12: ...the POWER MODE switch is ON the front panel mute switch turns the HR624 on or returns it to STANDBY mode as indicated by the power LED the power LED goes off when muted If the POWER MODE switch is in...

Page 13: ...hould use high quality shielded cable to connect the signal source to the SIGNAL INPUT jack on the HR624 Foil shielded cables such as Belden 8451 8761 or 9501 are commonly used for studio wiring Micro...

Page 14: ...evice on the same AC circuit as the monitor Dimmers cause buzzing noises Use an AC line filter or plug the monitor into a different AC circuit SERVICE INFO Details concerning Warranty Service are spel...

Page 15: ...U S versions of our monitors is available only from our factory located in sunny Woodinville Washington Service for monitors living outside the United States can be obtained through local dealers or d...

Page 16: ...l Protection Amplifier Shut Down Auto Reset Specifications Enclosure Materials and Construction 5 8 inch 16mm thick MDF construction with 1 inch 25 4mm thick MDF front panel with radiused edges to min...

Page 17: ...e Input Voltage and Power Power consumption Standby mode 12 watts Quiescent idle 20 watts Musical Program Loud mix 105 watts Both channels driven into resistive loading to 1 clipping LF 86W 4 HF 38W 8...

Page 18: ...put was pro vided from various and sundry interested parties including ourcolorfullyconvolutedcommunica tions connoisseur and Master Geek Ron Koliha and Linn Compton proofreader extraordinaire Finally...

Page 19: ...50 100 200 500 1k 2k 5k 10k Hz HR624 High Frequency EQ Filter Response dBu 40 10 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 2 4 6 8 20 20k 50 100 200 500 1k 2k 5k 10k Hz HR624 Low Frequen...

Page 20: ...rope Asia Central South America 425 487 4333 Middle East Africa 31 20 654 4000 Fax 425 487 4337 www mackie com E mail sales mackie com Some of the people at our factory who helped design build sell an...