![MachineryHouse Hafco MetalMaster HM-51B Operation Manual Download Page 14](http://html1.mh-extra.com/html/machineryhouse/hafco-metalmaster-hm-51b/hafco-metalmaster-hm-51b_operation-manual_3221475014.webp)
14
OPERATION MANUAL
The full-load current rating is the amperage a machine draws when running at 100% of the out-
put power. Where machines have more than one motor, the full load current is the
amperage drawn by the largest motor or a total of all the motors and electrical devices that
might operate at one time during normal operations.
Full-Load Current Rating for these machine at 240V is 13.6 Amps
It should be noted that the full-load current is not the maximum amount of amps that the
machine will draw. If the machine is overloaded, it will draw additional amps beyond the
full-load rating and if the machine is overloaded for a long period of time, damage, overheating,
or fire may be caused to the motor and circuitry.
This is especially true if connected to an undersized circuit or a long extension lead. To reduce
the risk of these hazards, avoid overloading the machine during operation and make
sure it is connected to a power supply circuit that meets the requirements.
3.5 FULL-LOAD CURRENT RATING
4. COMMISSIONING
4.1 BASIC CONTROLS
The following descriptions are supplied to give the help the operator develop an understanding
of the basic controls used to operate the milling machine. This knowledge will be necessary to
safely complete the Test Run later in this manual.
F
ig
. 4.1
Isolating Power Switch:
The switch is found on the
electrical control box mounted on the side of the
machine. The switch enables power to flow to the
machine when the “ON” is visible at the top of the
switch.
08/11/2019
Instructions Manual for HM-54GV (M579)
14