20
ADDR
:
001-H
BAUD RATE
:
9600
PARITY
:
NONE
PROTOCOL
:
PELCO-P
MODEL
:
SD66XX
TEMP : 032
℃
SOFTWARE
:
V1.00
BACK
EXIT
SYSTEM INFORMATION
DISPLAY SETTING
CAMERA SETTING
FUNCTION SETTING
ALARM
SETTING
EXIT
z
Please make sure all the cable connections are right.
4.2
Self-diagnosis System Information
After installation, please connect speed dome to power. The system goes on a self-diagnosis,
and then it pops up the above interface to show the system information.
If there is anything wrong during the self-diagnosis, system pops up error code.
The above interface disappears after speed dome received the first command (or the display
time lasts for 4 minutes.)
z
ADDR: Here you can view dome address information. For example, 001-H, 1 is the address
number, -H is hard address mode. –S is software address mode.
z
Baud rate: Dome communication baud rate.
z
Parity: Communication parity bit format.
z
Protocol: Current communication protocol.
z
Model: Dome type.
z
Temperature: Current dome internal temperature.
z
Software: Dome PTZ software version.
4.3
Main Menu
You can open the IP dome menu via control keyboard, matrix, or speed dome control terminal.
z
SYSTEM INFORMATION
:
Dome self-diagnosis information, address information, system
time setup, set north direction, language, factory default setup, reboot and so on.
z
DISPLAY INFORMATION: Display dome preset title, azimuth display, time, direction, dome
internal temperature, dome external temperature information.
z
CAMERA PARAMETERS
:
Display dome white balance setup, exposure setup, day/night
setup, focus setup.
z
FUNCTION SETTING
:
Set preset, pan, scan, auto cruise, pattern, idle motion, time task
and privacy mask function.
z
ALARM
SETTING
:
Set dome alarm number, action, contact, preset, scan, cruise, replay
out, reset delay, save setup and etc.