214657
204
Revision A
Figure 5.83: Stripper Plate Clearance
2.
Remove four bolts and nuts (A) from stripper plate (B).
3.
Replace stripper plate (B), secure with four bolts and
nuts (A), but do
NOT
fully tighten.
4.
Adjust the stripper plate (B) to achieve 3
–
8 mm
(1/8
–
5/16 in.) clearance (C) to auger flighting.
5.
Tighten nuts (A).
6.
Recheck the clearance.
5.6.5
Replacing Flighting Extensions
With header removed from combine, proceed as follows:
Figure 5.84: Auger Access Covers
1.
Remove two access covers (A) from both sides of the
center of the auger.
Figure 5.85: Flighting Extension
2.
Remove hardware (A) securing existing auger flighting
extensions (B), and remove extensions. Retain
hardware.