215922
306
Revision A
5.12
Every 1000 Hours
Complete the following maintenance tasks every 1000 hours of operation:
•
Change the fuel tank vent filter. For instructions, refer to
5.12.1 Removing and Installing Fuel Tank Vent Filter, page 306
.
•
Clean the DEF supply module filter. For instructions, refer to
5.12.2 Diesel Exhaust Fluid Supply Module Filter, page 308
•
Change the wheel drive lubricant. For instructions, refer to
5.6.6 Changing Wheel Drive Lubricant
5.12.1
Removing and Installing Fuel Tank Vent Filter
The fuel tank is vented by a hose and filter in the platform rail. Change the filter every 1000 hours or annually, whichever
occurs first.
Change the filter as follows:
DANGER
To prevent bodily injury or death from the unexpected startup of the machine, always stop the engine and remove the
key from the ignition before leaving the operator
’
s seat for any reason.
WARNING
To avoid personal injury or death from explosion or fire, do NOT smoke or allow flame or sparks near windrower when
servicing.
1.
Shut down the engine, and remove the key from the ignition.
ϭϬϯϴϲϬϴ
A
B
Figure 5.111: Right Service Platform
2.
Remove five bolts (A) and DEF tank cover (B) on the right
service platform.