Clock Programmer
User’s manual
ELETTRONICA
ELCO
3. Digital outputs
Pole No
Description
1
Blade downstroke solenoid valve
2
COMMON, Blade downstroke solenoid valve
3
4
COMMON, Blade downstroke solenoid valve
5
Blade upstroke solenoid valve
6
COMMON, Blade upstroke solenoid valve
7
Vice opening solenoid valve
8
COMMON, Vice opening solenoid valve
9
Vice closing solenoid valve
10
COMMON, Vice closing solenoid valve
11
Manual lock solenoid valve
12
COMMON, Manual lock solenoid valve
13
Fast blade downstroke solenoid valve
14
COMMON, Fast blade downstroke solenoid valve
15
Oil pump remote control switch
16
Coolant remote control switch
17
Blade motor remote control switch
18
Solenoid check valve
19
OUTPUT NEUTRAL / COMMON
20
PHASE
4. Analog inputs
Pole No
Description
35
Positive potentiometer power supply
36
Potentiometer input
37
Negative potentiometer power supply
Software operation
MACHINE START-UP AND RESET
On switching on, press the “RESET” button to position the machine - the blade moves all the way up to the limit
switch. At this point, the START led starts to blink.
SEMIAUTOMATIC CUTTING CYCLE
After carrying out machine reset, the control makes the start led blink – this only takes place if the bow is already found
at its limit switch.
If the machine is not in this condition, the start key led is switched off, and the reset key must be pressed again to move
the machine to its working position.
During machine operation, the coolant key led is switched on or off depending on the coolant reservation.
Cycle execution
1.
OIL PUMP ACTIVATION (IF NON ALREADY ACTIVE) WITH THE RESET KEY
2.
PRESS THE START KEY
3.
BLADE MOTOR ACTIVATION
4.
VICE CLOSING
5.
COOLANT ACTIVATION (IF RESERVED)
Page 4