INSTRUCTION MANUAL

Read and understand all of the instructions and safety

information in this manual before operating this product.

MAN-070 REV A

03/2018

© 2017 MAC Medical, Inc.

WORK TABLES

(Manual and Electric Height Adjust)

Summary of Contents for WT0003

Page 1: ...ON MANUAL Read and understand all of the instructions and safety information in this manual before operating this product MAN 070 REV A 03 2018 2017 MAC Medical Inc WORK TABLES Manual and Electric Height Adjust ...

Page 2: ...ons 3 GENERAL SPECIFICATIONS 4 Table Installation 4 UNPACKING INSTRUCTIONS 5 MINIMUM MAXIMUM ADJUSTABLE HEIGHTS FOR A WORK TABLE 6 HEIGHT ADJUSTMENT MANUAL HYDRAULIC PUMP WITH HANDCRANK 7 HEIGHT ADJUSTMENT MOTORIZED ADJUSTABLE HYDRAULICS 8 Work Tables with Electroic Adjustable Height Option Control Panel Technical Data 8 Work Tables with Electronic Adjustable Height Option Control Panel Setup and ...

Page 3: ...ically friendly adjustable heights adjustable manually or electronically Manual adjustable height range 36 55 Electronic adjustable height range 36 43 H or U brace instead of Under Shelf Full base unit underneath Drawers under all sizes Stainless steel guard rails Multiple under shelves Model Numbers and Overall Dimensions Model Number Overall Dimensions Depth Width Height WT0003 36 24 36 WT0004 4...

Page 4: ...lation Work Tables with the Electronic Height Adjustment Option require a power source to operate the hydraulics system 1 Place the table so that its left side where its power unit is located is near a 120 VAC GFI power outlet 2 Plug in the table cord 3 On the initial start up set the maximum and minimum heights on the control pad as shown on page 9 and 10 4 After the initial start up and control ...

Page 5: ... surfaces with sharp edges IMPORTANT Wear gloves and eyewear during the unpacking operation Retain all shipping materials until the table is completely unpacked and inspected for damage 5 Use tin snips to cut the metal bands holding the box to the wooden skid Fig1 6 Remove metal staples holding one end of the packing carton together 7 Slide out table from side of packing carton with two attached c...

Page 6: ...tabletop The Maxumim height of a Manual Height Adjust WorkTable is 55 from floor to tabletop Minimum Maximum Adjustable Height Electronic Height Adjustment The Minimum height of an Electronic Adjust Work Table is 36 from floor to tabletop The Maximum height of an Electronic Height Adjust Work Table is 43 from floor to tabletop 55 Fig 3 Manual height adjust minimum maximum heights Fig 4 Electronic ...

Page 7: ... Hydraulic Pump with Handcrank Fig 5 6 the Handcrank can be folded to disappear under the table 1 Crank the table to the desired height 2 Pull the Crank outwards then rotate downward to fold the handle under the table Fig 7 Fig 5 Manual Hydraulic Pump with Handcrank Fig 7 Hydraulid Pump Handcrank unfolded and folded Fig 6 Hydraulic Pump and Handcrank Location ...

Page 8: ...es Electrical Specifications 4 Memory Positions Primary Voltage 120V 10A Digital Display of the height Engine Voltage 24 VDC Overload Protection Nominal Rating Approximately 340 VA Thermal Protection Standby Power 0 6W Nominal Speed 180 min 1 Protection Type IP 20 HEIGHT ADJUSTMENT MOTORIZED ADJUSTABLE HYDRAULICS Electric Motor with Hydraulic Pump Memory Control Pad Power Supply Fig 8 Memory Contr...

Page 9: ... minus e Moving up or down is not possible f Press the S green button to confirm g After the confirmation the display will flash US 036 EU 091 h Use the Up arrow button to move to the upper us 43 EU 109cm upper limit checking with a tape measure i The table will move at half speed and half power j Adjust the read out in US inches EU centimeters to reflect the upper position with the 1 button plus ...

Page 10: ...ess the down arrow The table will now move down Checking with a tape measure lower the table down to US 36 EU 91cm c Then hold 2 until it reads 000 Then press S to set It will then display 036 d Hold the Up arrow to US 43 EU 109cm check the height with the tape measure Then press 1 until it reads 109 Then press S to set 5 Setting of Indicated Height a Press the S button Display will read 5 b If th...

Page 11: ... Pad must be replaced due to damage first remove the existing Memory Control Pad 1 Unplug the table from its power souce 2 Remove four 1 4 screws attaching the Controller to the table mounting plate Fig 10 3 Unplug the old Memory Control Pad cord from the Power Supply Unit 4 Remove the old Memory Control Pad Fig 10 Remove old Memory Control Pad ...

Page 12: ...g the Memory Control Pad to the table mounting plate Fig 11 3 Plug the control pad cable into the round receptacle of the table Power Supply Unit 12 13 4 Plug the table cord back into its power source 5 Program the Replacement Memory Control Pad as shown on page 13 Item Part Description QTY 1 H0090 PBD 110 Memory Control Pad 1 with power cord 1 2 H0203 4 40 X 1 4 Screw With Internal Tooth Lock Was...

Page 13: ...ble will now move down Verify height of table is US 36 EU 91cm with a tape measure 5 Press and hold 2 button until 000 is displayed Press GREEN SET Button Display will now read 036 6 Press and hold UP Arrow until the table raises to US 43 EU 91cm Verify height of table is 43 with a tape measure 7 Press and hold 1 button until the display reads 109 Next press the S button 8 The Memory Control Pad i...

Page 14: ... pads Soft bristle brush Mild detergents Sodium Bicarbonate baking soda Distilled water pH rating 7 alone or with a mild detergent White vinegar in a spray bottle Isopropyl Alcohol Hospital grade non bleach disinfectants Cleaners approved for use on stainless steel Cleaning Stainless Steel Surfaces 1 Using a damp lint free cloth and approved cleaner wipe down the entire exterior surface of the sta...

Page 15: ...l 1 H0135 5 LSS 5 Swivel Caster w Brake 2 All 2 H0090 03 Hydraulic Pump with crank 1 All 1 2 2 The Work Table replacement parts listed on this page have been identified by MAC Medical as serviceable by facility personnel and are available for purchase To obtain MAC Medical certified parts and authorized services contact your MAC Medical representative ...

Page 16: ...factory It is the customer s responsibility to inspect the product for packaging damage before signing the BOL This warranty does not apply to products which have been subject to abuse misuse accident modification alteration tampering negligence lack of routine maintenance or misapplication or products that have been repaired by other than MAC Medical or its authorized representatives This warrant...