background image

MAC FAUCETS

Owner’s Manual

Models: FA43/FA444

      Installation procedure:

1.

Take a moment to view drawings and read “special Installation note” on page 3 of this manual before proceeding with 
installation. Connect Faucet Autmator models FA43/FA444 exactly as shown in drawing, with sensor cable connection 
at bottom. Failure to install Faucet Automator Models FA43/FA444 as shown will result in premature  product failure 

and will void all warranties including extended warranty.

2.

If using deck plate, affix plate on deck to faucet using supplied screws (most models). Install new faucet by placing sensor 
wire and hose (faucets with integral hose) through the hole designated for spout. Make sure that wire is not pinched or cut 
during installation. 

Cutting or severely crimping sensor wire will cause faucet to malfunction and will also void all 

warranties

.

3.

Faucets with integral hose go to step 5

. Slide retainer washer over faucet shank with set screw deep placed in shank groove. 

Insert sensor wire through special groove in washer. Install retainer nut over faucet shank and tighten. 

4.

Remove the stainless steel braided hose from package, fasten to faucet shank. 

Go to step 6.

5.

 Place rubber ring (if used) at the bottom of the faucet. Affix faucet above plate (if deck plate is used). Use 2 screws, 2 nuts, 
and 1 retainer washer to fasten faucet to deck.

6.

Locate spot on the wall that you feel comfortable installing Faucet Automator FA43/FA444. The spot selected should be 
within reach of braided hose and sensor wire. The selected spot should also be away from possible water contamination.

7.

Mount Faucet Automator FA43/FA444 using supplied fasteners. 

Be careful to mount box exactly as shown in drawings 

with sensor receptacle towards the bottom.

8.

Install shank hose to Faucet Automator’s water outlet (top).

9.

Align groove in sensor wire plug with pin in Faucet Automator FA43/FA444 sensor receptacle, insert plug into receptacle, 
fasten plug nut by hand only. 

DO NOT CROSS THREAD.

Before proceeding to step 9, purge both hot and cold water lines for at least a minute each at high volume. Purging water 
lines clears out dirt and debris that would otherwise find its way to screen filter within the solenoid valve.

10.

***For single water source system install 

cold water

 supply hose to Faucet Automator’s water inlet, 

absolutely 

 

 do not

 

  

substitute hot water for cold as this may lead to scalding injuries.

11.

***For dual water temp system install 

Optional

  mixing valve to Faucet Automator’s water inlet.

MAC Faucets makes 2 types of optional mixing valves, an above the sink mechanical valve and a below the sink 
mechanical valve. For thermostatic type valve, please consult your plumbing professional.

12.

Install hot and cold water to mixing valve in no particular order.

13.

Turn angle stops on. Check for leaks.

Operation:

1.

Place hands under spout and directly in front of neck mounted sensor, water will begin to flow out in less than a second, 
water flow rate is governed by aerator and supply pressure, water temperature is governed by selection at angle stops, as well 
as water temperature in supply pipes

. Please remember, automatic faucets employ “presence” not 

“motion” sensors. An idle object placed directly underneath spout will immediately 
activate faucet.

2. Remove hands and water will cease to flow within 1-3 seconds depending on model of faucet and on water pressure.
3. If hands are left underneath spout for 30 or 60 seconds (depending on model), water will automatically shut off. To initiate 

flow again move hands away from faucet and start at step 1.

4. When attempting to run water over small objects such as tooth brush, it may be necessary to bring object closer to sensor to 

initiate water flow, when water begins to flow, move object back under stream of water. Once user “gets the feel” of the 
faucet this step may be skipped. 

1

Summary of Contents for FA43

Page 1: ...groove in sensor wire plug with pin in Faucet Automator FA43 FA444 sensor receptacle insert plug into receptacle fasten plug nut by hand only DO NOT CROSS THREAD Before proceeding to step 9 purge both hot and cold water lines for at least a minute each at high volume Purging water lines clears out dirt and debris that would otherwise find its way to screen filter within the solenoid valve 10 For s...

Page 2: ...improperly plug sensor wire properly Please call MAC Faucets for instructions 5 Sink is raised above counter and blocking sensor s vision reinstall properly Faucet does not operate red light blinks in response to approaching objects 1 No water very low water pressure in supply pipes supply valves closed 2 Water pressure very high well above 115 PSI 3 Screen filter severely clogged up 4 Supply hose...

Page 3: ...applications This faucet is not designed for outdoor applications 2 Avoid installing your new faucet in direct sunlight Direct sunlight that is focused on sensor will temporarily disable faucet s sensing capabilities 3 If you choose to install your faucet to one water source only do not install to hot water only as this may result in scalding injury 4 Important Before connecting supply line to Fau...

Page 4: ...or improper application will void this warranty Defective products must be shipped with postage and handling prepaid along with dated proof of purchase This warranty does not cover installation or any other labor charges it does not cover shipping and handling of both replacement parts and returned defective parts Products or components that have been altered or in any way modified will not be cov...