MPWP1800-3
by MacAllister
Getting
started...
EN
11
General
>
Rated voltage/frequency
>
Maximum permissible mains impedance
:
220 – 240 V ~ / 50 Hz
>
Rated input
:
1800 W
:
0.275 Ω
>
Rated pressure
:
9.5 MPa
>
Max. allowable pressure
:
14 MPa
>
Max. inlet water pressure
:
1 MPa
>
:
5.5l/min
>
:
7.33l/min
>
Rated temperature
:
50°C
>
Gun kickback force at max. pressure
>
Protection class
>
Degree of protection
>
Weight
>
Dimensions
:
12.6 N
:
II
:
IPX5
:
11 kg
:
351 X 408 X 855 mm
High pressure hose
>
Allowable pressure
:
20 MPa
>
Maximum temperature
:
60 °C
>
Length
:
8 m
Water hose (not supplied)
>
Quality
:
reinforced PVC hose
>
Diameter
:
min. Ø 12.7 mm (½“)
>
Max. length
:
10 m
Sound level
>
Sound pressure level L
pA
:
78.8 dB(A)
>
Uncertainty K
pA
:
2.50 dB(A)
>
Measured sound power level L
WA
:
90.3 dB(A)
>
Uncertainty K
WA
:
2.50 dB(A)
>
Guaranteed sound power level L
WA
(acc. to 2000/14/EC amended by
:
93 dB(A)
2005/88/EC)
Vibration level
>
Declared vibration emission value a
hd
:
<2.5 m/s²
>
Uncertainty K
:
1.0 m/s²
The sound values have been determined according to noise test code given in
EN 60335-2-79, using the basic standards ISO 3744 and ISO 11203.
The sound intensity level for the operator may exceed 80 dB(A) and ear protection
measures are necessary.
The declared vibration value has been measured in accordance with a standard
test method (according to EN 60335-2-79) and may be used for comparing
one product with another. The declared vibration value may also be used in a
preliminary assessment of exposure.
MNL_MPWP1800-3_MAC_GB_V6_200527.indd 11
5/27/20 5:54 PM