Air regulator installation and operation 

 

1.

 

Firmly tight and seal the copper air hole at IN and OUT terminal by high pressure 
rubber tube firmly . 

2.

 

Tight and seal the meter with meter face rubber tube. 

3.

 

Fix the connecting shelf with screw as the regulator position. 

4.

 

Get down the plastic screw and fix the regulator on the shelf. 

5.

 

Turn  on  the  air  valve,  turn  up  the  pressure  adjusting  knob,  Turn  the  pressure  to 

rated  volume(meter  inside  shows  KG),  and  then  put  down  the  knob.(+  means 

increasing pressure, -- means decreasing pressure.) 

                                                                                                                                         

6.

 

Scale of the meter is as follow. The volume in the picture is 6 kg. 

7.

 

If the  water in the  gas filtering bottle is too much, please turn on the water valve 

to let the water go out.

 

 

Regulator installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
INSTALLATION 

 

 

 

 

Summary of Contents for CUT 40

Page 1: ...PLASMA CUTTER OWNER S MANUAL MODEL CUT 40 60 POWER v MOS CONTROLIED PLASMA CUTTING POWER SUPPLY ...

Page 2: ...wer is used volume and weight of main transformer has reduced substantially and efficiency has been increased by 30 Piloting arc system can strike arc easily with principle of high frequency oscillation It has functions that it can supply gas ahead and turn off gas delayed cutting machine has characteristics as following 1 Stabilizing 2 Reliability 3 Lightness 4 Energy saving and no noise 5 High c...

Page 3: ...e phase 220V 15 Three phase 380V 15 Rated input power KVA 6 6 7 9 No load voltage v 230 295 Rated input current A 30 12 Rated output voltage v 96 104 Duty cycle 60 60 Pilot arc model HF oscillating HF oscillating Burner inter diameter mm 1 0 1 2 Pressure of air compressor kg 4 5 4 5 Thickness mm 1 12 1 20 Weight kg 9 19 Dimensions mm 371 153 232 480 204 303 ...

Page 4: ...YF 22 A2 3 The panel picture above is for reference only If any difference with the real machine please follow with the real machine INSTALLATION ...

Page 5: ...n 4 Get down the plastic screw and fix the regulator on the shelf 5 Turn on the air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows KG and then put down the knob means increasing pressure means decreasing pressure 6 Scale of the meter is as follow The volume in the picture is 6 kg 7 If the water in the gas filtering bottle is too much please turn on t...

Page 6: ...obile plug of another end of earth cable is connected to positive terminal of front panel then tighten it 3 Make sure air plug of torch is connected to switch connector of panel If it is pilote arc cutter pilote arc cable of torch is connected to terminal of pilote arc wiring column CHECK 1 Check if cutting machine is grounded reliably according to standard 2 Check if all connectors are connected ...

Page 7: ... dust or corrosive gas in the air SAFTY 1 Make sure the working area is adequately ventilated Cutting machine is light and its structure is compact and the electromagnetic fields generated the high current So natural wind is not satisfy to cool down components there are two axial flow fan in inter machine in order to force to cool down it NOTES Exhaust shutter must not in block or covered it is 0 ...

Page 8: ... tip must not connect to work piece directly when user is cutting Torch should be inclined and it is 1 mm from inter hole of copper tip to work piece in order to protect copper tip 2 As arc supporting cutting machine if arc supporting frequency is down or there is no arc supporting user may be get rid of oxidized film of inter electrode by abrasive paper Then machine will be operated normally MAIN...

Page 9: ...and fan is working However press control knob of torch there is no HF arc striking sound and inter red diode is lit 1 Check if MOS K1170 of top board is damaged driver mould is damaged 2 Rising transformer of bottom board is damaged 3 Control mould is damaged 4 Switch indicator is lit and fan and electromagnetic valve are working However there is no sound of HF arc striking and inter red diode is ...

Page 10: ...here is no DC 24V output 3 Open the air switch fan and indicator are working Press knob of torch electromagnetic valve is starting there is no sound of HF arc striking and red diode is not lit There is some fault in part of arc striking such as 1 It is too far between discharge tip or there is adhesion in discharge tip 2 Primary coil of arc striking transformer is damaged or poor contact 3 Check i...