background image

GUIDELINES

FOR UNIT

INSTALLATION

Page 3

 

 10023034

Framing Requirements

Due to individual site variations, exact 

guidelines for every situation cannot be 

supplied. The recommended framing and 

dimensional requirements shown are 

for a typical application and may vary, 

depending on site requirements.

The dimensions shown in Figure 1 are from 

the surfaces where the unit will be attached. 

This surface can be bare studding, dry wall 

or other suitable underlayment material. It 

is important that the floor and all framing be 

square and level. Framing should be done 

using accepted materials and construction 

techniques, in accordance with all applicable 

codes.

NOTE:

 It is advisable to have the unit on 

site during the early stages of framing.

NOTE:

 Any preconstructed wall may require 

modifications or additional framing members 

to allow for pipes or fittings which protrude 

from the unit on whirlpool equipped models, 

for proper unit installation.

NOTE:  A pump access is MANDATORY 

on all whirlpool equipped models.

 

Additional access areas may be necessary 

to comply with code requirements. Figure 1.

Installation Procedure

With the unit positioned in the alcove, several 

details must be checked prior to securing the 

unit in place (Figures 2a & 2b);

ü

  Confirm unit apron is resting flush on the 

floor.

ü

 Confirm drain position.

ü

 Confirm the unit is level along each side 

and each end.

ü

 Confirm the unit is square in the alcove 

 

framework.

ü

 Confirm the front inside corner is plumb 

at each end. (This is critical for the 

proper installation of an enclosure)

ON WHIRLPOOL EQUIPPED UNIT

ü

 Check for required modifications to 

framing due to whirlpool components. 

The unit must be positioned square in 

the alcove framework. The use of shim 

or filler material behind the fastening 

flange at each framing member may 

be required to maintain the unit in the 

proper position.

If the unit is a whirlpool with an alternate 

pump mounting, refer to the special 

alternate pump location supplement at 

this time.

Drain Cut-Out

(Left End Drain)

Drain Cut-Out

(Center Drain)

21" W x 16" H

Pump Access

Mandatory

on All Whirlpool

Equiped Units

Fixture

Blocks

Finished Unit Dept

h

Minimum Alcove Dept

h

Unit Rough-In Dept

h

Drain Center

Alcove Lenght / Unit Lenght

Drain Cut-Out

Drain

Cut-Out

B

C

D

5"

F

E

A

NOTE: Left End Drain Installation Illustrated

Finished Unit Dept

h

Minimum Alcove Dept

h

Unit Rough-In Dept

h

Drain Center

Drain Center

Alcove Lenght / Unit Lenght

Drain

Cut-Out

B

C

D

5"

F

E

A

NOTE: Center Drain Installation Illustrated

MODEL

141082 GT4260 L/R

141082 GT4260 Center Drain

141083 GT60

A

60"
60"
60"

B

42"
42"
49"

C

40-1/2"
40-1/2"
47-1/2"

D

19-1/4"
11-1/4"
11-1/4"

E

9-1/2"

30"
30"

F

12-1/2"
12-1/2"
14-1/4"

Figure 1 - Alcove Framing Guidelines

Drain

Center

141482 GT4260AP

60"

42"

40-1/2"

11-1/4"

30"

12-1/2"