background image

 

MA onPC 

command wing 

 

Data 

 

Transport 

 

Safety 

instructions 

 

Safety and 

environmet 

 

Quickstart  

Connect 

 

Quickstart  

ON / OFF 

 

Maintenance 

 

Conformity 

 

 

25 

Symbols and warning labels 
 

 

 

 
 
 

I   0 

 
 
 

 
 

Warning  

 

Danger Area

 

 
 
 

 
 

Warning  

 

Danger of electric 

shock

 

 
 

 
 

Supply 

voltage 

ON/OFF 

 
 

Alternating 

current 

(AC) 

 

 

 

Dispose of as 

hazardous 

waste.  

Follow the local 

applicable 

regulations!  

 

 

 

MA onPC 

command wing 

 

Data 

 

Transport 

 

Safety 

instructions 

 

Safety and 

environmet 

 

Quickstart  

Connect 

 

Quickstart  

ON / OFF 

 

Maintenance 

 

Conformity 

 

 

25 

Symbols and warning labels 
 

 

 

 
 
 

I   0 

 
 
 

 
 

Warning  

 

Danger Area

 

 
 
 

 
 

Warning  

 

Danger of electric 

shock

 

 
 

 
 

Supply 

voltage 

ON/OFF 

 
 

Alternating 

current 

(AC) 

 

 

 

Dispose of as 

hazardous 

waste.  

Follow the local 

applicable 

regulations!  

 

 

Summary of Contents for MA onPC

Page 1: ...com 2012 MA Lighting International MA onPC command wing QuickMAnual Version XII 04 deutsch english MA Lighting International GmbH An der Talle 24 28 33102 Paderborn Germany Phone 49 5251 688865 10 Fa...

Page 2: ...hange without notification We do not assume liability for any incorrect information in this booklet Vervielf ltigung oder Ver ffentlichung dieses Booklets auch teilweise in jeglicher Form nur mit schr...

Page 3: ...Theatern den Einstieg in die MA Lighting Familie praktische L sungen zum Backup oder Preprogramming 01 MA onPC command wing Small in size but big in detail Einfach nur mit einem PC oder Notebook verbi...

Page 4: ...r Theater sowie f rs Programmieren zuhause Und er ist der perfekte Einstieg in die MA Lighting Welt 02 MA onPC command wing Der grandMA2 onPC command wing besitzt nicht nur die sprichw rtliche MA Zuve...

Page 5: ...ner Produktion stecken bei der pl tzlich Schwierigkeiten auftreten Vielen Danke f r Ihr Verst ndnis MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 6: ...utor 2x A B Fader 100mm Grandmaster Fader 60mm Level Wheel Slot f r Kensington Lock Diebstahlschutz MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 7: ...oder St rungen der Funktion auftreten D h beide Ger te PC und grandMA2 command wing m ssen an derselben Steckdose oder wenn erkennbar am selben Stromnetz Schutzleiter Potential identisch angeschlossen...

Page 8: ...ne Teile Tasten oder Steckern das Ger t nicht anschlie en Unsere Service Hotline hilft Ihnen weiter MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 9: ...r AN AUS Wechsel strom AC Das Ger t muss separat entsorgt werden Die rtlichen Vorschriften beachten MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 10: ...abst rzt Wir versichern Ihnen jedoch dass wir unser M glichstes tun um diese Abst rze zu vermeiden MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 11: ...eile freigelegt werden Neben anderen Risiken besteht hierbei die Gefahr eines elektrischen Schlages MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 12: ...ch tzt deshalb nicht in der N he von Wasser betreiben Das Ger t nicht im Regen oder Nebel betreiben MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 13: ...f r den PC onPC und den MA onPC command wing verwenden sonst k nnen nach dem Verbinden ber USB Sch den an der Hardware und oder St rungen der Funktion auftreten D h beide Ger te PC und grandMA2 onPC c...

Page 14: ...OUT Max 3072 Parameter 4 DMX OUT nur der h chstwertige Node ist aktiv Max 4096 Parameter 6 DMX OUT Connect Beispiele MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect...

Page 15: ...Node 4096 Parameter 6 DMX OUT PC MA onPC command wing NPU als 4 Port Node 4096 Parameter 6 DMX OUT MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 16: ...binden Das Ger t besitzt eine eingebaute PSU und stellt sich automatisch ein 90 240V 50 60Hz UNBEDINGT DIE HINWEISE AUF SEITE 5 BEACHTEN Einschalten Den Hauptschalter an der R ckseite auf Position I s...

Page 17: ...en Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF Wartung Konformit t 15 MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 18: ...h use des entsprechenden Steckers verbunden sein Waldb ttelbrunn 20 01 2012 Dipl Ing Michael Adenau MA onPC command wing Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF...

Page 19: ...ort finden sie auch die Systemvoraussetzungen die f r den Betrieb auf ihrem Computer notwendig sind grandMA2 onPC 17 Dieses Software Tool beinhaltet alle Funktionen einer echten grandMA2 Konsole ist n...

Page 20: ...Sequenzen und Effekten ist Familientradition und braucht eigentlich nicht extra erw hnt zu werden 18 und die anderen Mitglieder der grandMA2 Familie grandMA2 full size grandMA2 light grandMA2 ultra li...

Page 21: ...ubs programming in a theatre auditorium as well as preprogramming entering the world of MA Lighting 19 MA onPC command wing Small in size but big in detail Just connect via USB to any notebook or PC r...

Page 22: ...amming Furthermore it is the perfect choice for any MA enthusiast to enter the world of MA lighting 20 MA onPC command wing The MA onPC command wing incorporates the famous MA reliability and MA s ext...

Page 23: ...called show stoppers for people being in trouble out in the field Thank you for your understanding MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 24: ...x A B Fader 100mm Grandmaster Fader 60mm Level wheel Slot for Kensington Lock anti theft protection MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 25: ...of hardware and or malfunction can result from connecting via the USB cable That means both units PC and grandMA2 onPC command wing must be connected to the same power socket or if guaranteed to the s...

Page 26: ...or faders are damaged do not connect the apparatus to power Call our hotline for technical support MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 27: ...ON OFF Alternating current AC Dispose of as hazardous waste Follow the local applicable regulations MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 28: ...RNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 29: ...ng and or removing coverings besides harm to others you run the risk of suffering an electric shock MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 30: ...inst splash water Do not use this apparatus near water Do not use the apparatus in rain or moisture MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 31: ...h conductor for PC onPC and grandMA2 onPC command wing otherwise damages of hardware and or malfunction can result from connecting via USB cable That means both units PC and grandMA2 onPC command wing...

Page 32: ...ignificant node counts Max 2048 parameters 2 DMX OUT Max 4096 parameters 6 DMX OUT Connect examples MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 33: ...t Node 4096 Parameter 6 DMX OUT PC MA onPC command wing NPU as 4 Port Node 4096 Parameter 6 DMX OUT Connect Limits MA onPC command wing Data Transport Safety instructions Safety and environmet Quickst...

Page 34: ...power supply The command wing is equipped with a PSU 90 240V 50 60Hz PAY ATTENTION TO DETAILS ON PAGE 23 ON Set the mains switch on the rear side of the command wing to I Note Flashing executor button...

Page 35: ...en opening and or removing coverings besides others you run the risk of suffering an electric shock MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 36: ...ng resp to the housing of the corresponding plug Waldb ttelbrunn 20 01 2012 Dipl Ing Michael Adenau MA onPC command wing Data Transport Safety instructions Safety and environmet Quickstart Connect Qui...

Page 37: ...d free of charge at www malighting com There you will find the relevant system requirements as well grandMA2 onPC 35 This software tool incorporates all functions of a real grandMA2 console It communi...

Page 38: ...way of programming including nearly infinite numbers of presets cues pages sequences and effects 36 and the other members of the grandMA2 family grandMA2 full size grandMA2 light grandMA2 ultra light...

Page 39: ...PC command wing Optionen options Seriennummer serial number Baujahr year of manufacture Distributor 37 Ger tetyp model MA onPC command wing Optionen options Seriennummer serial number Baujahr year of...

Page 40: ...38 Notizen notes 38 Notizen notes...

Page 41: ...com 2012 MA Lighting International MA onPC command wing QuickMAnual Version XII 04 deutsch english MA Lighting International GmbH An der Talle 24 28 33102 Paderborn Germany Phone 49 5251 688865 10 Fa...

Reviews: