INSTALLATION INSTRUCTIONS:

Connect the  MA SEVEN WAY BOOSTER to your DMX equipment.

>

NOTE:

The LOAD (rotary) switch is usually set to position "0" or "1".
Select the appropriate termination resistor, if the connected unit is the last DMX
receiver.

Connect unit to your DMX source (e.g. lighting consoles)

LEDs "Signal In" and "Signal Out" should now be lit.

NOTE:

The brightness of LED "Signal In" depends of the DMX signal.

ERROR HANDLING:

Check fuse if the booster fails to function.

Under normal operating conditions, the "SIGNAL OK" and "SIGNAL IN" LEDs are on.

ERRORS may be caused by:

Contact problems with cables and connectors
Short circuit and/or wrong pinlayout
Lack of shield, lacking data line
Lack of termination resistor
Inappropriate cable or extreme cable length

>

NOTE:

In case of unit failure, "DMX THRU" will still operate!

-- THE UNIT IS NOW READY FOR USE --

 LOAD      0       1     2     3     4     5      6       7      8      9

  OHM     5k    1k   500   300  220   180  150  120  100    90