background image

Disabling a wireless sensor 

You can disable single wireless sensor from the RControl Admin portal. Go to the RControl Alarm menu, 

RF Zones tab, and choose Enabled=No for that particular sensor. 

Deleting all keyfobs and wireless detectors 

 Press and hold the white button of the RF receiver 3 times for around 10 seconds, until the LED indicator 

goes OFF each time. This will delete ALL the paired keyfobs and wireless detectors from the memory.   

  NOTE: 

This procedure will delete 

all paired keyfobs and wireless detectors

! To pair the keyfobs  

 and the wireless detectors again, you should repeat the pairing procedure for each keyfob and  
 detector.  

  NOTE:

 Before you start the deleting procedure make sure the panel is 

DISARMED

 NOTE:

 All the other settings will not be deleted, e.g. Entry/Exit Delay time, Partition configurations etc. If 

you want to change those setting you must log in the RControl Admin Portal.  

Keypads 

The RControl-RF-KB version of the alarm panel supports 1404RKZ and 1555RKZ DSC  keypads.  

The keypad should be powered from AUX(+) and AUX(-).  
Connect terminal R (RED) of the keypad to AUX(+) of the alarm panel. 
Connect terminal B (BLK) of the keypad to AUX(-) of the alarm panel. 
Connect terminal G (GRN) of the keypad to terminal A of the alarm panel. 
Connect terminal Y (YEL) of the keypad to terminal B of the alarm panel. 
 

The default keypad user code of the alarm panels is “1234”. 

 

The user code can be changed by the end user via the RControl mobile application (refer to section 
RControl Mobile Application) 

RControl Mobile Application 

The RControl mobile application is available for Android, iOS and Windows Phones.  

With the 

RControl

 mobile application the end user can:

 

 

Monitor the status of the alarm panel 

 

View events log up to one year back in time 

 

Remotely Arm/Disarm the alarm system 

 
The application can be download by scanning the following QR codes: 

 

 

 

Initial end user login credentials for the app are provided with the alarm panel. 
At the first login, it is strongly recommended that the end user changes the User name and Password and 

provides an email for password recovery. 

 

 

Summary of Contents for RControl MQ03SD-RCALARM-RF

Page 1: ...r building M8 Sofia 1309 Bulgaria Web Site www m2mservices com M2M Services Ltd RControl Alarm MQ03SD RCALARM RF Installer s Manual V 1 6 M2M Services Ltd 1 Kukush Str building M8 Sofia 1309 Bulgaria...

Page 2: ...Wired and wireless detectors 5 Adding wired detectors 5 Pairing a wireless detector 5 Pairing wireless panic button 6 Disabling a wireless sensor 7 Deleting all keyfobs and wireless detectors 7 Keypad...

Page 3: ...process in the most commonly used scenario when only instant zones with no entry exit times are needed By default all wired zones of the alarm panel are initially set to SMART Enroll type When a new...

Page 4: ...which will not allow you to pair the next keyfobs before you disarm the panel The learning mode lasts 10 seconds If the receiver does not receive signal from the keyfob in the timeframe of 10 seconds...

Page 5: ...automatically receive labels Keyfob 101 Keyfob 116 These labels appears in the mobile application when arming disarming with keyfob You can change the keyfob labelling anytime from the RControl Admin...

Page 6: ...nitializes wait for the LED to stop blinking Enter in learning mode press the white button on the RF receiver Activate the sensor twice by moving in front of the sensor activate the sensor once and wa...

Page 7: ...of the alarm panel supports 1404RKZ and 1555RKZ DSC keypads The keypad should be powered from AUX and AUX Connect terminal R RED of the keypad to AUX of the alarm panel Connect terminal B BLK of the k...

Page 8: ...Account No 0000 Periodical tests interval in this field you can configure the interval for the periodical test messages in seconds that the alarm panel will send NOTE This interval is different from...

Page 9: ...le time You can configure this from section Report All During Alarm Cycle If this setting is disabled only the initial violation will be reported and all following activations will not be reported unt...

Page 10: ...configuring a 24h Panic zone of the panel you can also use the built in panic button of the wireless keyfob For firmware versions higher than 6 5 22 it is disabled by default You can enable the panic...

Reviews: