General Specifications 

 

Built-in GPRS communicator 

 

Remote control via Smartphone 

 

2 Partitions 

 

8 Wired zones 

 

32 Wireless zones 

 

Supports up to 16 keyfobs with rolling code 

 

1 bell output and 1 programmable output (open collector 500mA) 

 

Short circuit protection of the AUX 

Wiring the RControl Alarm panel  

Wiring the power supply module  

• 

The L and N terminals should be connected to the powerline (220V)  

• 

The -V output should be connected to the (-) of the alarm panel  

• 

The +V output should be connected to the (+) of the alarm panel  

Wiring a siren  

The siren should be connected to AUX(+) and BELL(-). The programmable output for the siren BELL(-) is 

an open collector 500mA.  

SMARTEnroll 

 self-learning zones  

RControl Alarm panel supports SMARTEnroll feature 

 preconfigured settings and self-learning zones, 

which in most cases eliminate the need of initial programming of the alarm panel. This simplifies the 
installation process in the most commonly used scenario, when only instant zones with no entry/exit 
times are needed.  

By default, all wired zones of the alarm panel are initially 

set to “S

MART 

Enroll”

 type. When a new wired 

detector is connected to any zone (when the zone is closed), the zone is registered automatically and 
the panel starts monitoring that zone. Zones Z1-Z7 are self-registered as instant zones and zone Z8 

 as a 

tamper zone (24h Tamper). When a new zone is being self-registered, the panel reports an event 

“Added module, Zone N” with ContactID E

-531.  

By default, when a zone is not used it should not be short circuited to the AUX(-). However, if a zone is 

already self-registered and will be no longer used, it should be short circuited to the AUX(-) or it should 

be disabled, as described in section “Configuring the zones of 

RControl Alarm panel

”. 

 

When you pair a wireless zone it also automatically registers as instant zone.  

If the default configurations are not suitable, the zones can be configured from the RControl Admin 

Portal, as 

described in the section “Configuring the zones of 

RControl Alarm panel

”. 

 

Summary of Contents for RControl MQ03SD-RCALARM-RF

Page 1: ...r building M8 Sofia 1309 Bulgaria Web Site www m2mservices com M2M Services Ltd RControl Alarm MQ03SD RCALARM RF Installer s Manual V 1 6 M2M Services Ltd 1 Kukush Str building M8 Sofia 1309 Bulgaria...

Page 2: ...Wired and wireless detectors 5 Adding wired detectors 5 Pairing a wireless detector 5 Pairing wireless panic button 6 Disabling a wireless sensor 7 Deleting all keyfobs and wireless detectors 7 Keypad...

Page 3: ...process in the most commonly used scenario when only instant zones with no entry exit times are needed By default all wired zones of the alarm panel are initially set to SMART Enroll type When a new...

Page 4: ...which will not allow you to pair the next keyfobs before you disarm the panel The learning mode lasts 10 seconds If the receiver does not receive signal from the keyfob in the timeframe of 10 seconds...

Page 5: ...automatically receive labels Keyfob 101 Keyfob 116 These labels appears in the mobile application when arming disarming with keyfob You can change the keyfob labelling anytime from the RControl Admin...

Page 6: ...nitializes wait for the LED to stop blinking Enter in learning mode press the white button on the RF receiver Activate the sensor twice by moving in front of the sensor activate the sensor once and wa...

Page 7: ...of the alarm panel supports 1404RKZ and 1555RKZ DSC keypads The keypad should be powered from AUX and AUX Connect terminal R RED of the keypad to AUX of the alarm panel Connect terminal B BLK of the k...

Page 8: ...Account No 0000 Periodical tests interval in this field you can configure the interval for the periodical test messages in seconds that the alarm panel will send NOTE This interval is different from...

Page 9: ...le time You can configure this from section Report All During Alarm Cycle If this setting is disabled only the initial violation will be reported and all following activations will not be reported unt...

Page 10: ...configuring a 24h Panic zone of the panel you can also use the built in panic button of the wireless keyfob For firmware versions higher than 6 5 22 it is disabled by default You can enable the panic...