background image

 M2M Services Ltd, 1 Kukush Str, building M8, Sofia 1309, Bulgaria, Web Site: www.m2mservices.com  

 

 

 

 

 

 

 

 

M2M Services Ltd. 

 

  

 

RControl Alarm 

MQ03SD-RCALARM-RF  

Installer

’s

 Manual V 1.6

 

 

M2M Services Ltd, 1 Kukush Str, building M8, Sofia 1309, Bulgaria, Web Site: www.m2mservices.com  

Summary of Contents for RControl MQ03SD-RCALARM-RF

Page 1: ...r building M8 Sofia 1309 Bulgaria Web Site www m2mservices com M2M Services Ltd RControl Alarm MQ03SD RCALARM RF Installer s Manual V 1 6 M2M Services Ltd 1 Kukush Str building M8 Sofia 1309 Bulgaria...

Page 2: ...Wired and wireless detectors 5 Adding wired detectors 5 Pairing a wireless detector 5 Pairing wireless panic button 6 Disabling a wireless sensor 7 Deleting all keyfobs and wireless detectors 7 Keypad...

Page 3: ...process in the most commonly used scenario when only instant zones with no entry exit times are needed By default all wired zones of the alarm panel are initially set to SMART Enroll type When a new...

Page 4: ...which will not allow you to pair the next keyfobs before you disarm the panel The learning mode lasts 10 seconds If the receiver does not receive signal from the keyfob in the timeframe of 10 seconds...

Page 5: ...automatically receive labels Keyfob 101 Keyfob 116 These labels appears in the mobile application when arming disarming with keyfob You can change the keyfob labelling anytime from the RControl Admin...

Page 6: ...nitializes wait for the LED to stop blinking Enter in learning mode press the white button on the RF receiver Activate the sensor twice by moving in front of the sensor activate the sensor once and wa...

Page 7: ...of the alarm panel supports 1404RKZ and 1555RKZ DSC keypads The keypad should be powered from AUX and AUX Connect terminal R RED of the keypad to AUX of the alarm panel Connect terminal B BLK of the k...

Page 8: ...Account No 0000 Periodical tests interval in this field you can configure the interval for the periodical test messages in seconds that the alarm panel will send NOTE This interval is different from...

Page 9: ...le time You can configure this from section Report All During Alarm Cycle If this setting is disabled only the initial violation will be reported and all following activations will not be reported unt...

Page 10: ...configuring a 24h Panic zone of the panel you can also use the built in panic button of the wireless keyfob For firmware versions higher than 6 5 22 it is disabled by default You can enable the panic...

Reviews: