4.1 Period
Period is the interval (in minutes) between one measure and the next one. The sensor sends two measures for every transmission (each one with its own timestamp),
so the messages interval is twice the period value. Value can be between 15 and 65535 minutes.
Period interval can be set with App or with downlink command.
The device sends extra reports when the measurement changes in accordance with the set thresholds.
4.2 Temperature
4.3 Pressure
4.3.1 Altitude compensation
When the sensor is not installed at the sea level, the reading of barometric pressures at other elevations must be compensated. Set the right altitude value with LoRa
Tool app:
Value can be from -300 to 3000 meters.
Altitude can also be set with downlink command.