Update the sensor with LoRaTool:

 

During the update, do not move the smartphone untill the end message.

 

3 LEDs

 

On the MCF-LW12CO2E there are two system leds, green and red.

 

Red light status can be related to the values of bVOC, depending on enabled thresholds.

 

4. Measures

 

Summary of Contents for MCF-LW12VOC

Page 1: ...Directive 2012 19 EU of the European Parliament on waste electrical and electronic equipment WEEE and pursuant to and in accordance with Article 20 of the Directive 2013 56 EU of the European Parliam...

Page 2: ...ry life SF 12 15minutes reading period Battery capacity included 14400mAh NFCfor node configuration FW update and data reading Indoor installation Storagetemperature 20 80 C Operatingtemperature 10 60...

Page 3: ...or has restarted 2 3 Power ON OFF The sensor is shipped completely off to prevent battery consumption during storage It istherefore necessary to carry out afirst power on prior to commissioning There...

Page 4: ...onfigured Slow flashing Joining Sending Receiving Steadystate Data error Connection error 2 5Battery This sensor contains lithium battery which must be disposed of separately MCF LW12VOCisprovided wit...

Page 5: ...5873860 detach the batteries from the electronic board batteries are secured with dual locking tape and disconnect from the connectors Connect the new batteries and put them in place replace the tape...

Page 6: ...to be resetted Toperform the operation you need aunique reset code that must be requested to enginko please provide the DevEUI of the sensor when you ask for that code Atthe end of the procedure the...

Page 7: ...860 Updatethe sensor with LoRaTool During the update do not move the smartphone untill the end message 3LEDs Onthe MCF LW12CO2E there are two system leds green and red Red light status can be related...

Page 8: ...between 15and 65535 minutes Period interval can be set with App or with downlink command The device sends extra reports when the measurement changes in accordance with the set thresholds 4 2Temperatur...

Page 9: ...value of aVOC mixture named bVOC breath VOC not biogenic calibrated as in the table Molar fractionCompound 5ppm 10ppm 10ppm 50ppm 15ppm Carrier gas Nitrogen 4 6 2 1Extended ppb Asdefault VOC values c...

Page 10: ...alling below the negative thresholds leds change accordingly and the device sends anew uplink with the new leds status and the latest measures Thresholds can be enabled disabled and set via NFC with L...

Page 11: ...b 5 1Activation The device supports the following activations on aLoRaWAN network 1 NONE sensor not activated 2 OTAA the JoinEUI and the AppKey not setted must be written to the device 3 OTAAMCF88 Ove...

Page 12: ...instead public 0x34 butthe NS must be setted accordingly default public Band selectthe right LoRaWAN band settings accodingly to country requirements DST setto change DST default none Notime sync set...

Page 13: ...passwords to avoid unauthorized persons to read data or modify parameters Asdefault passwords are equal to 0 Allowedvalues range from 0to 99999999 only numbers To change the passwords set the new valu...

Page 14: ...nstead to manually adjust the parameters for details about the file format please ask to enginko This isvery useful especially in case of multiple devices configuration With Save button an XML file wi...

Page 15: ...abled if the DevEUI of the device matches one of the DevEUIs in the XLS file LoRa parameters will be setted fromthis one These configuration can be done in the in the Settings Enable or disable the us...

Page 16: ...0 925 MCF LW12VOC US enginko LoRaWAN indoor environmental sensor VOC LUX US902 928 MCF LW12VOC AUenginkoLoRaWAN indoor environmental sensor VOC LUX AU915 928 11 Declaration of conformity Hereby engink...