8
Wireless DATA Tranceiver Manual
9
Wireless DATA Tranceiver Manual
1. SELECT ANEMOMETER OR CCTV SYSTEM
2.
SELECT TRANSMISSION OR RECEIVING MODE
3.
RESETTING MODE
4.
Select Existence of Temperature/Humidity Sensor.
ON
1
ON
1
ON
4
ON
4
ON
2
ON
2
ON
3
ON
3
ADDRESS SETTING
SET1 SETTING
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
F000
Switch Setup Code
F0D7
Switch Setup Code
The maximum number of ID allowed in ID setting is 65,536; however, 256 IDs
were preset by the factory default setting; therefore, the actual number of ID
available for user’ setting is 256 for setting the group.
s
If switch is set as shown in the picture to the left, group is F000
If switch is set as shown in the picture to the left, group is F0D7
1. Make sure that the power is off.
2. Lift the number 3 SET1 switch up to ON.
3. Set Address switch to the appropriate group referring to the above picture.
4. Turning the power on, RXD and TXD LED will flicker 8 times. At last, the address(ID)
has changed.
5. Lower number 3 SET1 switch to OFF to avoid repetition of the above process
whenever the power is on. In doing so, the frequency setting is skipped, and the
device will function normally.
The operation of SET1 switch can cover the conversion of send/receiving mode, anemometer,
CCTV mode, and resetting of the frequency and ID; the setting can be done as shown in the
below picture.
SW-#2 = Off : RF Transmission mode.
RS-485 Receiving mode.
SW-#2 = On : RF Receiving mode.
RS-485 Transmission mode.
Set ID, frequency, send/receiving mode, anemometer, and CCTV
mode, etc. with turning the power off, and turn the power on after
lifting the number 3 switch of SET1 as shown in the picture to the
left, then RXD and TXD LED will blink 8 times, and the setting will
be complete.
Once the above setting is complete, lower the number 3 switch of
SET1 as shown in the picture on the left to avoid resetting ID,
frequency, and more whenever the power is on.
If number 4 switch of SET1 is in lower position as shown in the
picture on the left, there is no sensor. As conversion is not allowed
when power is on, do the setting before the power is turned on.
If number 4 switch of SET1 is in upper position as shown in the
picture to the left, then the sensor is there.