7 .3.17.6 VOX Delay Time Adjust Mode
Used switch
I
SW!tch opeflJ!lon
• To enter the vox Deloy 1tne Adµ! Mode. Pf'G$I [MBIIU] swttch ror one second and Pf'G$I [MBIIU]
sv.11ch momentclly nYe !Trnes.
• To� the VOX Deloy Time, rotote thl!I [CH] knob or press MIC [UPJ/lDNJ 5Witch.
• To decide the VOX Delay lime, pnm [MENU) switch for one second or prms [MBIIU) sv.11ch
momentclly.
Used Indicator
lhls function Is p�ble, JI only al the flme ol VOX Function On.
vex
Delay nma ls Iha time before stopphg
vex
1ransmls!lon aflar the Input to a microphone stopped. This ad)usffng mode
Jets delay time ror 1ha VOX 1mnJmls51on to be ftrlshed. II can adjust the nine stap.s.
Whle VOX Delay Tmc, Aqjwl Mode, "VOX" icon appeas and the selected VOX delay lime wll blnk on the lowest di9"1 of
Config1XO!ion lndcalor. Al Iris mode, •
S "
blinks on higher digits ol Conflg1XC!lon Indicator.
1. When rotate the [CHJ knob to clockwise direction
or
MIC [UP] switch i.! pressed, VOX delay time is increased as
fa lows.
1 (short delay time/ --, 2--, 3 --, • • • 7 --, 8 --, 9pong delay time)
2. When rotate the [CHJ knob to counrerclockwise direction
or
MIC [ON] switch is pressed, VOX delay time is
decreased as follows.
1 (short delay time/ +- 2 +- 3 +- • • • 7 <--- 8 <---9pong delay !!ma)
7.3.18. VOX Mode
A VOX l'Jnction is on outomotic tn:msmitting function by ,peaking into PTT microphone or VOX microphone without pres,ing
[P'Tl] switch. And aulomotically reh.ms to receiving when stop spea<ing.
A VOX function usually uses PTT mlcft!Phone. When oplfonal VOX microphone Is connected to VOX MIC JACK of raar P<Jnel,
VOX tn:mJmwlon by PTT rrlcropl1one 15 not performed, but ii becomes VOX tronsrru.slon by VOX microphone.
• " VOX "icon appears while VOX Mode On, and" VOX" icon cf1SOppeas whle VOX Mode Off.
• • VOX " Icon blnks at the slluaflon that Anfl VOX having acted proolblls lrammlsslon.
• TlmJmlsslon by (P'Tl] switch Is avalabla dumg VOX Mode On. Whan (PTT) switch Is prassed whla tn::msmlsslon by
VOX !unction. then It chang115 to 1rarumlsslon by (P'Tl] switch. Whla (PTT) switch 15 pnwlng, 1Tansrrl5Slon by VOX
function is unavalable.
TABLE 7-3-18-1. VOX MIC Sensl!Mty Laval Ad)usl
Sensitivity Level
2
3
4
5
6
7
8
9
Sensitivity
high
>
>
>
mid
>
>
>
low
TABLE 7-3-18-2. Anfi VOX Level Adjust
AnH VOX Level
0
2
3
4
5
6
7
8
9
Level
OFF
high
>
>
>
mid
>
>
>
low
TABLE 7-3-18-3. VOX Delay Tlma Adjust
Delay lime
1
2
3
4
5
6
7
8
9
nme (sec.)
0.2
0..4
0.6
0.8
1.2
1.5
2
3
p.16