INSTALLATION
■
CAUTION
• IP 55 is ensured for the front panel of the unit mounted
independently to a panel. Test the sealing at the mount-
ing surface once the device is installed.
• Set the unit on a vertical surface with its digital meter at
the top side. Mounting in other directions may cause heat
built up inside the unit and shorten its life or degrade its
performance.
• Ensure that there is sufficient space for ventilation inside
a panel. Do not install above the devices that generate
high heat such as heaters, transformers or resistors.
Observe at the minimum of 30 mm (1.2”) in all directions
for maintenance purpose (e.g. wiring, removing or install-
ing).
■
HOW TO MOUNT THE UNIT ON A PANEL
1) Remove both mounting brackets.
2) Detach the terminal cover and insert it first and then the
module itself into the cutout hole. (The cover is slightly
wider than the module.)
3) Put and slide the brackets back into the holes at the top
and the bottom and tighten them until the module is
firmly fixed.
■
HOW TO REMOVE THE TERMINAL COVER
Insert the minus tip of a screwdriver into each hole at the
four corners of the cover and pull it to the direction as indi-
cated below to separate the terminal block cover.
■
HOW TO REPLACE THE SCALE PLATE
13
8
68
[68+72×(n - 1)]
+1
0
+0.7
0
Panel thickness 2.3 – 20
13
8
+1 0
+1
0
■
PANEL CUTOUT unit: mm
• Single mounting
• Clustered mounting
n = number of units
Panel
Mounting Bracket
Pull up the part ‘A’ when replacing the scale plate.
Body
Scale Plate
A