background image

R8-DC4C

P. 3 / 4

EM-9743 Rev.1

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

Phone: +81(6)6659-8201   Fax: +81(6)6659-8510   E-mail: [email protected]

COMPONENT IDENTIFICATION

RUN

Module Address Setting

Rotary SW

Function Setting

DIP SW

Terminator DIP SW

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

SW1

x10

1 2 3 4 5 6 7 8

x1

SW2

SW4

SW3

Term

On

On

Status Indicator LED

Output Status Indicator LED

Internal Bus Connector

Output Connectors

   

FRONT VIEW

   

SIDE VIEW

CARD ADD.

DO1

DO2

DO3

DO4

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

 INDICATOR LED

LED

OPERATION

FUNCTION

Status

OFF

Stopping

Green ON

Valid host communication

Green Blinking

Reading/writing configuration

Red ON

Setting error

Red Blinking

Parameter error

Output

Status

OFF

OFF

Green ON

ON

 OUTPUT CONNECTOR ASSIGNMENT

  PIN 

ID 

FUNCTION

  No.
  1 

DO 

Discrete output

  2 

NC 

No connection

  3 

 NC   No connection

  4 

DO 

Discrete output

1

2

3

4

 PC CONFIGURATOR

The following parameters can be set with using PC Configu-

rator Software (model: R8CFG):
• Output at the startup
• Output at the loss of communication
• Common setting (loss of internal bus communication de

-

tection time)

Turn SW4-8 ON to allow programming by the PC Configu

-

rator via the Power/Network Module.
Refer to the users manual for the R8CFG for detailed opera

-

tion of the software program.

 MODULE ADDRESS

 Module Address

The left switch determines the tenth place digit, while the

right switch does the ones place digit of the address.  

Address is selected between 0 to 31. 

(Factory setting: 0) 

Module Address Setting (x1)

Module Address Setting (x10)

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

 OPERATING MODE

*Factory setting

• Output at The Loss of Communication

OUTPUT AT THE LOSS OF COMMUNICATION

SW4-7

Output Hold (*)

(last data correctly rerceived is hold)

OFF

Stop output (Output fixed at OFF)

ON

• Configuration Mode

CONFIGURATION MODE

SW4-8

DIP switch setting (*)

OFF

PC Configurator and communicaton

ON

• Terminator DIP SW

TERMINATOR SW

SW3

Without (*)

OFF

With

ON

Caution

:  Be sure to set unused SW 4-1 through 4-6 to OFF.

Summary of Contents for R8-DC4C

Page 1: ...ty GENERAL PRECAUTIONS Before you remove or mount the unit turn off the power supply and output signal for safety Switches on the side of the module can be set for mainte nance only while the power supply is off Do not access them while the power is supplied ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ven t...

Page 2: ...ernal communication bus connector 2 I O modules cannot hold tightly on the DIN rail by themselves without power network module Secure them to the position if necessary by using DIN rail end plates Removing an intermediate module Protective Cover The protective cover is to be attached over the connected I O module at the right end Align the hooks on the cover with the grooves of the module and slid...

Page 3: ...OR The following parameters can be set with using PC Configu rator Software model R8CFG Output at the startup Output at the loss of communication Common setting loss of internal bus communication de tection time Turn SW4 8 ON to allow programming by the PC Configu rator via the Power Network Module Refer to the users manual for the R8CFG for detailed opera tion of the software program MODULE ADDRE...

Page 4: ...5 2 17 CONNECTION DIAGRAM NC NC 1 2 4 3 NC NC 1 2 4 3 OUTPUT CONNECTOR 1 OUTPUT CONNECTOR 4 INTERNAL BUS EXC SUPPLY BUS CONNECTOR INTERNAL POWER 1 1 Not used Do4 Do1 WIRING INSTRUCTIONS e CON connector connector XN2D 1474 S002 Omron Recommended cable connector XN2A 1470 Omron 1 Applicable wire size 0 08 mm2 AWG28 0 5 mm2 AWG20 Outer sheath diameter max 1 5 dia 1 The cable connector is not included...