R7L-DA16

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7804-F  Rev.10  P. 2 / 19

COMPONENT IDENTIFICATION

Discrete Input Status Indicator LED

ERR

SVCE

ONLINE

TX/RX

PWR

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

4

5

6

7

1

2

3

10 11 12 13

2

3

4

1

15 16 17 18

7

8

9

6

14

5

Reset SW

Factory Configuration Port

Service SW

Status Indicator LED

L

ON

W

ORKS

, Power Supply

Terminals

Input Terminals

 

STATUS INDICATOR LED

ID

COLOR

STATE

MEANING

PWR

Green

ON

Internal 5V is normal

OFF

Internal 5V is abnormal.

ONLINE Green

ON

Online

Blink

approx.

0.5 Hz

Offline
Sending/receiving of Net-
work
Variables has stopped.

Blink

approx.

2 Hz

Receiving Wink Message

OFF

Abnormal state

ERR

Red

ON

Writing in the non-volatile 
memory

Blink

Abnormal state

OFF

Normal state

TX/RX

Green

ON

Sending/receiving Network 
Variables

OFF

Communication is lost.

SVCE

Green

ON

No network information

Blink

approx.

0.5 Hz

Offline
Sending/receiving of Net-
work
Variables has stopped.

OFF

Normal state

 

DISCRETE INPUT STATUS INDICATOR LED

Used to show discrete input signal status.
     

ON  

: LED ON

     

OFF  : LED OFF

Note:  For firmware version 0.14 or smaller, when the discrete 

inputs are commissioned by LonMaker, the LEDs indi-
cate the status of them.

 

SERVICE SWITCH

Used to identify the node in L

ON

W

ORKS

 network configura-

tion.

 

RESET SWITCH

Used to reset the Neuron Chip.  Press the switch behind the 
front cover to reset.
Control functions are halted while completing resetting and 
restarting.  Confirm no danger before conducting resetting.

 

POWER SUPPLY, L

ON

W

ORKS

 TERMINAL ASSIGNMENT

4

NET1

5

NET2

6

U (+)

1

NET1

2

NET2

3

FG

7

V (–)

NO.

ID

FUNCTION, NOTES

1

NET1

L

ON

W

ORKS

 communication 1

2

NET2

L

ON

W

ORKS

 communication 2

3

FG

FG

4

NET1

L

ON

W

ORKS

 communication 1

5

NET2

L

ON

W

ORKS

 communication 2

6

U (+)

Power input

7

V (–)

Power input

Note:   L

ON

W

ORKS

 wiring must be paired between NET1 termi-

nals and/or NET2 terminals.

 

INPUT TERMINAL ASSIGNMENT

10

NC

11

X1

12

X3

1

COM

2

X0

3

X2

13

X5

4

X4

14

X7

5

X6

15

X9

6

X8

16

XB

7

XA

17

XD

8

XC

9

XE

18

XF

NO.

ID

FUNCTION

NO.

ID

FUNCTION

1

COM

Common

10

NC

No Connection

2

X0

Input 0

11

X1

Input 1

3

X2

Input 2

12

X3

Input 3

4

X4

Input 4

13

X5

Input 5

5

X6

Input 6

14

X7

Input 7

6

X8

Input 8

15

X9

Input 9

7

XA

Input 10

16

XB

Input 11

8

XC

Input 12

17

XD

Input 13

9

XE

Input 14

18

XF

Input 15

Summary of Contents for R7L-DA16

Page 1: ...nts When counter pulse and discrete are mixed and acquired make sufficient consideration to them Before you remove the unit or mount it turn off the power supply and input signal for safety ENVIRONMEN...

Page 2: ...Used to show discrete input signal status ON LED ON OFF LED OFF Note For firmware version 0 14 or smaller when the discrete inputs are commissioned by LonMaker the LEDs indi cate the status of them S...

Page 3: ...ide 54 2 13 17 66 4 5 6 7 1 2 3 10 11 12 13 2 3 4 1 15 16 17 18 7 8 9 6 14 5 3 12 5 5 22 50 1 97 18 5 73 115 4 53 7 M3 SCREW TERMINALS for LONWORKS POWER 18 M3 SCREW TERMINALS for INPUT 6 24 6 24 CONN...

Page 4: ...ONNECTION HOST PC LONWORKS R7L LONWORKS R7L LONWORKS Terminator WIRING INSTRUCTIONS SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal si...

Page 5: ...PToemType SCPTserialNumber Extension module setting Maximum sending time per fb Minimum sending time per fb Set Tag No name Indicate Model No and Version Indicate Serial No NodeObject Network Variable...

Page 6: ...0 0 0 Maximum time interval to send network variables per fb Power supply must be reset when this configuration property is changed Network variables are sent out in the specified intervals even when...

Page 7: ...CNTOut Set the maximum count Set the value when fbCNT is reset fbCNT SCPTdirection nviCNTIn SCPTinvrtOut nviCNTCtrl SCPTpwrUpState nvoCNTOut SCPTnvType SCPTmaxRnge SCPTsetpoint Network Variables Confi...

Page 8: ...N 1 Accumulated time of ON status Bit 7 Memory storage at the non volatile memory 0 Count retained in the memory and preset at the startup 1 Count always reset to 0 Bit 8 through 15 Invalid Minimum in...

Page 9: ...set signal Set output at nvoDIStat Combination Mode Refer to the table in the next page RS flip flop set signal Reset output at nvoDIArm fbDI SCPTdirection nvoDIStat SCPTinvrtOut nvoDIArm SCPTinvrtOut...

Page 10: ...NETWORK VARIABLE TYPE Range Default EXPLANATIONS nvoDIStat SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Contact input nvoDIStat and nvoDIArm Reference Table X0 X2 X4 X6 X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF...

Page 11: ...iCMPIn2 SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Connects to the network variable to be compared nvoCMPOut SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 nviCMPIn1 and nviCMPIn2 are compared OFF is output whe...

Page 12: ...In2 SNVT_switch nviENIn3 SNVT_switch nviENIn4 SNVT_switch nv 116 nv 119 nv 100 nv 103 nv 104 nv 107 nv 108 nv 111 nv 112 nv 115 Network Variables NETWORK VARIABLE TYPE Range Default EXPLANATIONS nviEN...

Page 13: ...NOut VALUE OFF OFF OFF OFF SCPTvalueDefinition 0 ON OFF OFF OFF SCPTvalueDefinition 1 OFF ON OFF OFF SCPTvalueDefinition 2 ON ON OFF OFF SCPTvalueDefinition 3 OFF OFF ON OFF SCPTvalueDefinition 4 ON O...

Page 14: ...s the timer function With Invalid nvoTMROut is reset to the default status and the internal counter is reset nvoTMROut SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Timer output Configuration Properties Com...

Page 15: ...ins on Set Invalid at nviTMRIn to turn nvoTMROut off Example Providing one shot output when nviTMRIn is turned on SCPTtimeout 0 One shot output delay time SCPTtimeout 1 Pulse width SCPTtimeout 2 800 1...

Page 16: ...riables Configuration Properties Extension discrete output Y0 Y2 Y4 Y6 Y8 YA YC YE Output nviDOEX1 status Y1 Y3 Y5 Y7 Y9 YB YD YF Output nviDOEX2 status nv 4 nv 11 nviDOEX1 SNVT_switch nv 12 nv 19 nvi...

Page 17: ...on or off Y1 Y3 Y5 Y7 Y9 YB YD YF of the extension module depending upon this input 100 0 1 ON Other OFF Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATION...

Page 18: ...X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF Normal Mode Status output at nvoDIEX1 Status output at nvoDIEX2 Combination Mode Refer to the table in the next page fbDIEX SCPTdirection nvoDIEX1 SCPTinvrtOut nvoD...

Page 19: ...4 X6 X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF nvoDIEX1 nvoDIEX2 OFF OFF 0 0 0 OFF Invalid ON OFF 100 0 1 ON Invalid OFF ON 0 0 0 OFF 0 0 0 OFF ON ON 100 0 1 ON 100 0 1 ON nvoDIEX2 SNVT_switch 0 0 0 100 0 1...