background image

R7D-SV4

EM-7802-A  Rev.7  P. 4 / 10

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

10 11 12 13

2

3

4

1

15 16 17 18

7

8

9

6

14

5

2 3 4

1

5

30 (1.18)

[5 (.20)]

3 (.12)

3 (.12)

5.5 (.22)

DIN RAIL

35mm wide

54 (2.13)

17 (.66)

50 (1.97)

18.5 (.73)

115 (4.53)

18–M3 SCREW 

TERMINALS

for INPUT

6 (.24)

TERMINAL BLOCK for

DeviceNet, POWER

 

CONNECTION DIAGRAM

1

VH0

10

VL0

11

I0

2

COM0

INPUT 0

3

VH1

12

VL1

13

I1

4

COM1

INPUT 1

6

VH2

15

VL2

16

I2

7

COM2

INPUT 2

8

VH3

17

VL3

18

I3

9

COM3

INPUT 3

■ 

Input Connection Examples

VHn

VLn

In

+

– COMn

WIDE SPAN

VOLTAGE

VHn

VLn

In

+

– COMn

NARROW SPAN

VOLTAGE

VHn

VLn

In

+

– COMn

Be sure to close across VLn and In terminals for a current input.

CURRENT

RANGE

CAN_L

V–

Drain

CAN_H

V+

EXTENSION CONNECTOR

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Summary of Contents for R7D-SV4/UL

Page 1: ...titude up to 2000 meters This equipment must be mounted inside a suitable fire enclosure This equipment is to be supplied by a Class 2 power sup ply CONFORMITY WITH EU DIRECTIVES The equipment must be...

Page 2: ...bps 1 250 kbps or 2 500 kbps For the settings 3 through 9 it analyzes the PLC s network to determine the baud rate on the network OPERATING MODE Factory setting Extension SW1 1 1 2 SW1 1 SW1 2 EXTENSI...

Page 3: ...ETTING Communication Timeout 0 0 3276 7 sec 1 0 sec Status Data ON Disable OFF Enable OFF Enable Serial ID English one byte characters within 8 characters CHANNEL INDIVIDUAL SETTING PARAMETER SETTING...

Page 4: ...PUT 6 24 TERMINAL BLOCK for DeviceNet POWER CONNECTION DIAGRAM 1 VH0 10 VL0 11 I0 2 COM0 INPUT 0 3 VH1 12 VL1 13 I1 4 COM1 INPUT 1 6 VH2 15 VL2 16 I2 7 COM2 INPUT 2 8 VH3 17 VL3 18 I3 9 COM3 INPUT 3 I...

Page 5: ...put Module Status CH0 CH1 CH2 Begin 0 Begin 0 1 2 CH3 3 4 Output Data Input Data None Example 1 Analog Input Module without Status Example 2 Analog Input Module R7D EC16x with Status R7D EC16x Input D...

Page 6: ...is added MODEL OUTPUT DATA 1 INPUT DATA 2 R7D to Master Master to R7D R7D EAx 1 0 R7D ECx 0 1 STATUS Status signal can be included in the transmission data when the setting is enabled using the PC Co...

Page 7: ...a thick cable to maintain low imped ance at high frequency Use shielded cables for the signals taken out of the control panel Choose a thick and short cable to ground the FG terminal of the R7D module...

Page 8: ...d the panel cover with an earth strap grounding may be strengthened and EMC may be improved Ground the control panel at low impedance using e g braided wires Keep the opening for ventilation as small...

Page 9: ...cautions are illustrated in the next page Keep cables as short as possible It prevents noise emissions from the cables and noise overlapping to the cables Attach a ferrite core to reduce noise impact...

Page 10: ...pplicable when wiring the R7D Series To external apparatus Keep the cable as short as possible To external apparatus Shielded Cable Earth Clamp Remove a part of the shielded cable cover and ground it...

Reviews: