background image

R30SV4

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-9001  Rev.2  P. 4 / 5

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)







⑭ ⑤










110 (4.33)

25 (.98)

98 (3.86)

20–M3
SCREW

6

(.24)

 

CONNECTION DIAGRAM

11

VH1

VL1

I1

COM1

2

12

1

18

9

19

8

VH4

VL4

I4

COM4

13

VH2

VL2

I2

COM2

4

14

3

16

VH3

VL3

I3

COM3

7

17

6

 

Input Connection Examples

VHn

In

COMn

VLn

Wide Span

Voltage

+

Narrow Span

Voltage

+

Current

+

VHn

In

COMn

VLn

VHn

In

COMn

VLn

Note: Connect either wide or narrow span or current terminals for each channel.

Note: Be sure to close across VLn and In terminals for a current input.

Input 1

Input 2

Input 3

Input 4

INTERNAL POWER 

INTERNAL BUS

BUS CONNECTOR

 

INPUT RANGE

• 

Wide span voltage

:  -10 – +10V DC, -5 – +5V DC,  

 

0 – 10V DC, 0 – 5V DC, 1 – 5V DC

• 

Narrow span voltage

:  -1 – +1V DC, 0 – 1V DC,  

 

-0.5 – +0.5V DC

• 

Current

: -20 – +20mA DC, 0 – 20mA DC, 4 – 20mA DC