INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Network module ..................................................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

 

CSP+ file

CSP+ file is downloadable at M-System’s web site (http://
www.msystem.co.jp) or CC-Link Partner Association’s web 
site (http://.cc-link.org). 

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• The equipment must be mounted inside the instrument 

panel of a metal enclosure.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

HOT SWAPPABLE MODULES

• It is possible to replace a module with the power supplied 

provided that the module is replaced with one with the 
same model number and installed in the same base slot.

• Be sure to replace a module when it is not communicating 

with the host as it may affect the system.  Note that re-
placing multiple modules at one time may greatly change 
line voltage levels.  We strongly recommend to replace 
them one by one.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 10 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

R3 I/O MODULE EXTENSION

• The internal bus communication period for R3 series I/O 

modules installed on the R30EBS is as follows.
Internal bus communication period = 6 msec. x number of
I/O 10 msec. (Data update period of main CPU)

Example: Four R3 I/O modules

6 msec. x 4 + 10 msec. = 34 msec.

Even when the R30EBS is mounted to the R30BS, the
internal bus communication period of R30 series is kept 
to approx. 1 msec.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

NETWORK MODULE

(CC-Link IE TSN network)

MODEL

R30NCIT1

Summary of Contents for R30NCIT1

Page 1: ...e is replaced with one with the same model number and installed in the same base slot Be sure to replace a module when it is not communicating with the host as it may affect the system Note that re placing multiple modules at one time may greatly change line voltage levels We strongly recommend to replace them one by one ENVIRONMENT Indoor use When heavy dust or metal particles are present in the ...

Page 2: ...N1 Receiving Data ON Abnormality receiving data OFF Normality receiving data CN2 LINK Green CN2 Linking Up ON Linking up OFF Link down L ER Red CN2 Receiving Data ON Abnormality receiving data OFF Normal IP ADDRESS STATION NO SETTING ROTARY SW Set the fourth octet of IP address and station No with two rotary switches The upper rotary SW sets the upper digits MSB and the lower rotary SW sets the lo...

Page 3: ...gage the positioning guide of the module with the In stallation Base 2 Pivot the module on the positioning guide and press it down until the lock tab clicks into place Positioning Guide 3 Tighten the base fixing screw using a screwdriver stem length 70 mm 2 76 or more torque 0 5 N m Base Fixing Screw HOW TO REMOVE THE MODULE 1 Loosen the base fixing screw using a screwdriver stem length 70 mm 2 76...

Page 4: ...t the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 110 4 33 25 98 98 3 86 CONNECTION DIAGRAM CC Link IE TSN CN1 CC Link IE TSN CN2 Regarding CN1 and CN2 of RJ 45 connector for CC Link IE TSN network there is no restriction for connection order INTERNAL BUS INTERNAL POWER RJ 45 MODULAR JACK RJ 45 MODULAR JACK USB CONNECTOR PC CONFIGURATOR CONNECTOR BUS CONNECTOR ...

Page 5: ... 4 5 R30XN16A 1 6 R30XN16A 1 7 R30YN16A 1 8 R30YN16A 1 R30EBS04 1 R3 SV8 8 2 R3 YV8 8 3 R3 DA32A 2 4 R3 DC32A 2 0 15 RWr n 0 Slot 1 2 4 6 8 10 12 14 Slot 2 Slot 3 Slot 4 INPUT DATA The figure below shows the data sent from the device to the master 16 Slot 6 Slot 5 Slot 7 Slot 8 R30SV4 R30YN16A R30YN16A R30XN16A R30XN16A CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 R30TS4 R30US2 R30YV4 1...

Page 6: ...ent output current in error e g load unconnected RX n 4 0 to RX n 4 F indicate error status for each module of R3 series The bit corresponding to such module turns to 1 as described below R3 TSx R3 RSx R3 US4 input burnout R3 DA16A input power in error or disconnected R3 YSx output current error e g load unconnected R3 PC16A external power supply in error or disconnected Data Error Status RX n 5 0...

Page 7: ...y data With C temperature unit raw data is multiplied by 10 For example 25 5 C is converted into 255 With F temperature unit the integer section of raw data is directly converted into the data For example 135 4 F is con verted into 135 Minus temperature is converted into negative values represented in 2 s complements 0 15 ANALOG DATA 16 bit data models R30CT4E etc 16 bit binary data Integer that e...

Page 8: ... ku Osaka 557 0063 JAPAN Phone 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 8902 Rev 1 P 8 16 DISCRETE DATA models R30XN16A R30YN16x etc 0 15 Input 1 Output 1 Input 2 Output 2 Input 3 Output 3 Input 16 Output 16 0 OFF 1 ON ...

Page 9: ... GX Works3 REGISTRATION FOR PROFILE This unit supports CC Link Family system profile CSP CSP can be downloaded from the M System s web site http www msystem co jp or CC Link Partner Association s web site http www cc link org However registration of CSP is optional If CSP is not needed skip this section and move on to Construction of System 1 Start GX Works3 2 From the main menu select Tool Regist...

Page 10: ...tation Local Station and Remote Station R30NCIT1 are connected by Ethernet cable CN1 and CN2 of CC Link IE TSN Network RJ 45 modular jacks can be connected in any order Before wiring make sure to turn off the power of each unit 2 After wiring is completed turn on each unit CREATION OF PROJECT Connect the PC and the master station and create a project of the master station with GX Works3 installed ...

Page 11: ... 81 6 6659 8510 E mail info m system co jp EM 8902 Rev 1 P 11 16 4 In the following window when Module Label Not use is displayed in Module Setting click Setting Change to open the option window and change to Use Click Select Yes for Use Module Label in Operation Setting and click OK Click ...

Page 12: ... 5 Double click Module Configuration in the Navigation window to open the Module Configuration window According to the real PLC configuration select the module from POU List of the Element Selection window and drag and drop it to the module configuration diagram Drag Drop 6 Double click CC Link IE TSN network module to open the parameter setting window ...

Page 13: ... 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 8902 Rev 1 P 13 16 7 Set Station Type to Master Station Network No to 1 in Required Settings 8 Click Detailed Setting of Network Configuration Settings in Basic Settings to display the CC IE TSN Configuration window ...

Page 14: ... Rev 1 P 14 16 According to the real system configuration select the device from Module List and drag and drop it to the device configura tion diagram Click Close with Reflecting Setting When CSP not registered select General CC IE TSN Module Drag Drop Click 9 Click Detailed Setting of Refresh Setting to display the Refresh Setting window ...

Page 15: ... 0063 JAPAN Phone 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 8902 Rev 1 P 15 16 Assign link devices RX RY RWr RWw to devices of the CPU unit click Apply to close the window Click 10 Click Convert Convert to execute conversion Select ...

Page 16: ... Osaka 557 0063 JAPAN Phone 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 8902 Rev 1 P 16 16 11 Click Write to PLC in Online on menu bar to open Online Data Operation window Select Check necessary items and click Execute Click ...

Reviews: