INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

One-shot pulse output module ...........................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• The equipment must be mounted inside the instrument 

panel of a metal enclosure.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

HOT SWAPPABLE MODULES

• Replacing the module does not affect other modules on 

the same base.  Thus, the module can be replaced while 
the power is ON.  However, replacing multiple modules 
at once may greatly change live voltage levels.  We highly 
recommend to replace them one by one.

• ON/OFF control output mode and One-shot output mode 

have the function of preventing erroneous output right 
after hot swapping modules.  Data is synchronized with 
data stored in the interface module in the initial commu-
nication after hot swapping.

   Data will not be output from a channel even if ‘1’ is previ-

ously written in Do before hot swapping or the PLC/PC 
writes ‘1’ to Do when communication has started after hot 
swapping.  Be sure to write ‘0’ then ‘1’ to Do in the initial 
communication.

   When R3-PD16C is used in combination with a Modbus 

interface module (model: R3-NM1, R3-NE1, etc.) that 
does not support cyclic communication, be sure to write 
output data immediately before hot swapping.

 

GENERAL PRECAUTIONS

• DO NOT set the switches on the module while the power 

is supplied.  The switches are used only for maintenance 
without the power.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

AND ....

• When the pause period set in the PLC/PC is long, internal 

data of R3-PD16C will be cleared due to communication 
timeout.  In order to hold the internal data, set the time-
out period so as to be longer than the pause period via the 
PC configurator software (model:R3CON). 

INSTALLATION

Use the Installation Base (model: R3-BSx).

ONE-SHOT PULSE OUTPUT MODULE

(PNP transistor output, 16 points)

MODEL

R3-PD16C

Summary of Contents for R3-PD16C

Page 1: ...er hot swapping modules Data is synchronized with data stored in the interface module in the initial commu nication after hot swapping Data will not be output from a channel even if 1 is previ ously written in Do before hot swapping or the PLC PC writes 1 to Do when communication has started after hot swapping Be sure to write 0 then 1 to Do in the initial communication When R3 PD16C is used in co...

Page 2: ...odel R3 NC1 NC3 NE1 NM1 and NDx of firmware version V2 00 or higher Other interface modules are not compatible So set I O Mode as output SW2 7 ON to use it Note 1 R3 NL1 and R3 NL2 are not available with this model ON OFF Control Output Channel SW2 8 ON OFF control output channel is swappable with its pair SW ON OFF CONTROL OUTPUT CHANNEL Not Swapped Swapped SW2 8 OFF ON Output Hold Function SW3 1...

Page 3: ...3 Ch1 One Shot Output Completion 4 5 7 8 9 2 One Shot Output ON OFF CONTROL OUTPUT MODE Data Length 16 bits Example that ON OFF control outputs sequentially Ch1 to Ch2 to Ch2 is shown below Example of when I O Mode is in Output Operation SW2 7 OFF and ON OFF Control channel is Not Swapped SW2 8 OFF 1 Output data Do 1 changes from 0 to 1 2 After Do 1 s rising edge Ch1 s one shot output turns ON for...

Page 4: ...pletion Di 2 Ch2 output completed status changes from 0 to 1 4 When Do 1 changes from 1 to 0 Di 2 changes from 1 to 0 5 After Do 1 s sinking edge Ch1 s one shot output turns ON for a fixed period of time SW1 s time set 6 After one shot output completion Di 1 Ch1 output completed status changes from 0 to 1 Do 1 Ch2 Ch1 1 4 3 Ch2 One Shot Output Completion 6 Ch1 One Shot Output Completion Note Durin...

Page 5: ...mpletion Status 0 Ch5 Output Completion Reset Do 6 1 Ch6 Output Di 6 Ch6 Output Completion Status 0 Ch6 Output Completion Reset Do 7 1 Ch7 Output Di 7 Ch7 Output Completion Status 0 Ch7 Output Completion Reset Do 8 1 Ch8 Output Di 8 Ch8 Output Completion Status 0 Ch8 Output Completion Reset Do 9 1 Ch9 Output Di 9 Ch9 Output Completion Status 0 Ch9 Output Completion Reset Do 10 1 Ch10 Output Di 10 ...

Page 6: ...Output Completion Status 0 1 Ch8 Output Di 8 Ch8 Output Completion Status 1 1 Output Data Reset Do 9 Do 10 0 0 Not Operating 1 0 Ch9 Output Di 9 Ch9 Output Completion Status 0 1 Ch10 Output Di 10 Ch10 Output Completion Status 1 1 Output Data Reset Do 11 Do 12 0 0 Not Operating 1 0 Ch11 Output Di 11 Ch11 Output Completion Status 0 1 Ch12 Output Di 12 Ch12 Output Completion Status 1 1 Output Data Re...

Page 7: ...he case of Not Swapped SW2 8 OFF ON OFF control output is swapped with its pair when SW2 8 is ON The following is an example of Do 1 Do WRITE ONE SHOT OUTPUT RESET Di OUTPUT COMPLETION STATUS Do 1 0 Ch2 Output Di 2 Ch2 Output Completion Status 1 Ch1 Output Di 1 Ch1 Output Completion Status CONTINUANCE OUTPUT MODE Do 1 through 16 are assigned to and Ch1 through 16 When data Do is 1 output is ON and...

Page 8: ... length ON OFF control mode Do 9 through Do 16 are unavailable Di 0 15 Di 1 Di 2 Di 3 Di 16 Note Di data is not practical discrete input data It is output completion status internal data TERMINAL CONNECTIONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 1 11 12 13 14 15 16 17 18 19 20 2 3 4 5 6 7 8 9 10 130 5 12 27 5 1 08 109 4 29 POSITIONING GUIDE TERMINAL COVER 20 M3 ...

Page 9: ...ing tongue terminal size Spade tongue type is also applicable Solder less terminals with insulation sleeve do not fit Applicable wire size 0 3 0 5 mm2 Recommended manufacturer Japan Solderless Terminal MFG Co Ltd Nichifu Co Ltd 12max 6max 3max 4min 3 2 dia mm FUNCTIONS OUTPUT HOLD or OUTPUT OFF In normal conditions the module outputs the signal from the preferred bus A When an error is detected th...

Reviews: