INSTRUCTION MANUAL

INSTALLATION BASE

MODEL

R10-BS1

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Installation base ..................................................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• The equipment must be mounted inside the instrument 

panel of a metal enclosure.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply, input and output signals for safety.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 10 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

INSTALLATION

Slider

Specification

(side)

Slider

Mounting Unit Cursor Key

Mounting Unit Lock Slot

1

6

10

9

7

5

4

2

3

8

11

20

19

18

17

16

15

14

13

12

Note: The side of mounting unit lock slot have No. 1 – 10 

terminal connections.

 

TERMINAL ASSIGNMENT

1

6

2

3

4

5

7

8

9

10

11

16

12

13

14

15

17

18

19

20

IO1

IO4

IO6

IO10

IO9

IO8

IO7

IO5

IO3

IO2

FE

DB

DA

NC

FE1

SLD DG

NC

24V

0V

PIN 

NO.

ID

FUNCTION

PIN 

NO.

ID

FUNCTION

1

IO1

I/O Terminal 1

11

FE

Modbus ground

2

IO2

I/O Terminal 2

12

DB

DB

3

IO3

I/O Terminal 3

13

DA

DA

4

IO4

I/O Terminal 4

14

NC

Unused

5

IO5

I/O Terminal 5

15

FE1

Power ground

6

IO6

I/O Terminal 6

16

SLD Shield

7

IO7

I/O Terminal 7

17

DG

DG

8

IO8

I/O Terminal 8

18

NC

Unused

9

IO9

I/O Terminal 9

19

24V

Power supply 24V DC

10

IO10 I/O Terminal 10

20

0V

Power supply 0V DC

Summary of Contents for R10-BS1

Page 1: ...r supply input and output signals for safety ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ventilation Do not install the unit where it is subjected to continuous vibration Do not subject the unit to physical impact Environmental temperature must be within 10 to 55 C 14 to 131 F with relative humidity within ...

Page 2: ...IN rail B Push the lower part of the unit in the direction of the ar row until the unit is firmly fixed to the DIN rail A B Removing the unit A Push down the DIN rail adaptor using a minus screw driver B Pull out the lower part of the unit C Remove the upper part from the DIN rail A B C WALL MOUNTING Referring to MOUNTING REQUIREMENTS unit mm inch on page 3 pull out the upper and lower sliders of ...

Page 3: ...the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch DIN rail 35mm wide 1 6 10 9 7 5 4 2 3 8 11 20 19 18 17 16 15 14 13 12 36 1 42 7 28 5 20 89 3 50 5 20 7 28 80 3 15 45 1 77 4 16 MOUNTING REQUIREMENTS unit mm inch 99 3 90 2 M4 CONNECTION DIAGRAM 1 2 3 4 5 6 7 8 9 10 CN 11 12 13 16 17 15 19 20 I O module DB DA DG FE SLD FE1 24V DC 0V DC Modbus Power input I O ...

Page 4: ...S FOR BASE SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal size Spade tongue type is also applicable Recommended manufacturer Japan Solderless Terminal MFG Co Ltd Nichifu Co ltd Solderless terminals with in sulation sleeve do not fit Applicable wire size 0 25 to 1 65 mm2 6max 3max 4min 3 2 dia mm ...

Reviews: