INSTRUCTION MANUAL

PATLABOR

WIRELESS TOWER LIGHT

(small size, 60 mm dia., Modbus-RTU transparent 900MHz band wireless 

device (child), 1 - 5 layers)

MODEL

IT60SW6F

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Tower Light .........................................................................(1)
Antenna ...............................................................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.
For information on the introduction of wireless device, refer 
to the 900 MHz band wireless device operating manual 
(EM-9085-B).
For information on Modbus specification, refer to the Mod-
bus Protocol Reference Guide (EM-5650).
These manuals are downloadable at M-System’s web site 
(http://www.m-system.co.jp).

POINTS OF CAUTION

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

  24 V DC rating: 24 V ±10%, approx. 7W

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and input signal for safety.

• The unit must not be subjected to external force.
• Do not rub the unit with organic solvent such as paint 

thinner.

 

ENVIRONMENT

• Indoor use.
• Attach the antenna to the unit.
• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 10 to 90% RH 
in order to ensure adequate life span and operation.

• Mount the unit on a flat and robust plate.
• Lamps are omnidirectional.
• The buzzer sound is directional in front of the unit.
• This unit communicates by radio waves.  Do not install the 

unit where it could be exposed to radio waves obstacles or 
strong electric fields.

• How to change antenna angle:  Rotate the antenna after 

loosening the connector nut (refer to the next drawing).  
Tighten the nut with torque (0.98 N·m) while holding the 
antenna pointing to the intended direction.  Otherwise, 
tight manually the nut, and assure it turning 10° to 15° 
more with a wrench.

Connector Nut

 

INGRESS PROTECTION (IP65)

• The IP code is conformable when the unit is mounted ver-

tically, antenna is installed and the control panel cover is 
locked.  The compartment, where connectors are located, 
is not protected.

• When opening the control panel cover, avoid humidity 

and dust penetration.  Dry and clean it if condensation is 
formed, and close the cover locking tightly.

• Install the antenna and tighten the connector nut tightly.
• In order to protect ingress of water or dust into the bot-

tom compartment, mount the unit on the flat plane, and 
be sure that the gasket does not roll back or dust is not 
on the gasket.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

• Cables to the unit must be wired indoor.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

Summary of Contents for PATLABOR IT60SW6F

Page 1: ...ected to continuous vibration Do not subject the unit to physical impact Environmental temperature must be within 10 to 55 C 14 to 131 F with relative humidity within 10 to 90 RH in order to ensure ad...

Page 2: ...designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy a...

Page 3: ...with 0 5 Hz in establishing wire less link Off when wireless link stops working 920Run Green On when wireless communication with child device is in normal status Off at a wireless communication error...

Page 4: ...er of devices in a network Child fixed 1 to 30 devices Child fixed 31 to 60 devices Child fixed 61 to 100 devices Child fixed child moving Child fixed 1 to 30 devices Set network quality Standard reco...

Page 5: ...elow EXTERNAL DIMENSIONS unit mm A 192 224 256 288 320 352 Control Panel Cover Antenna 60 Approx 1500 Lead wires R165 1 Consult M System for other bolt length 0 1 2 3 4 5 Lamp Layers 60 1 5dia A 4 85...

Page 6: ...Configurator 1 Example of 5 layers in order red yellow green blue and white Lamp and wire color are the same 2 When selecting the same color for more than one layer cable colors comply with ordering...

Page 7: ...mm2 Phoenix Contact AI0 75 10GY 0 75 mm2 Phoenix Contact MODBUS FUNCTION CODES SUPPORTED CODES DATA AND CONTROL FUNCTIONS CODE NAME 01 Read Coil Status Digital output from the slave read write 02 Read...

Page 8: ...On Output 2 Lamp 3 0 Off 1 On Input 2 Lamp 3 0 Off 1 On Output 3 Lamp 4 0 Off 1 On Input 3 Lamp 4 0 Off 1 On Output 4 Lamp 5 0 Off 1 On Input 4 Lamp 5 0 Off 1 On Output 5 Buzzer 0 Off 1 Continuous Inp...