COMPONENT IDENTIFICATION

5

4

3

2

2

1

0

9

8

7

6

5

4

3

1

0

9

8

7

6

5

4

3

2 1 0 9

8

7

6

Power

Run

Link COL

Link100

Power Link COL

Run Link100

Mode

Ethernet
Modular Jack

 BOTTOM VIEW

 

FRONT VIEW (with the cover open)

FRONT

IP Address Reset

Lamp 1

Lamp 2

Lamp 3

Lamp 4

Buzzer Aperture

Status Indicator LED

DIP SW

Gasket

Lamp 5

 

STATUS INDICATOR

ID

COLOR

FUNCTION

Power

Green

Turns on when the power is sup-
plied normally.

Run

Green

Turns on in normal communications 
conditions.

Link

Green

Turns on in Link status.

Link100

Green

Blinks when the module is  
transmitting/receiving. *

1

COL

Green

Blinks in case of collisions.

*1. Used only in 100BASE link.  Dark in 10BASE link.

 

OPERATING MODE

(*) Factory setting

• 

Lamp Blinking Frequency: Mode-1

Mode-1

LAMP BLINKING FREQUENCY

OFF

Approx. 2 Hz (*)

ON

Approx. 10 Hz

• 

Buzzer Intermittent Frequency: Mode-2

Mode-2

BUZZER INTERMITTENT FREQUENCY

OFF

Approx. 2 Hz (*)

ON

Approx. 10 Hz

• 

Buzzer Volume: Mode-3, Mode-4

Mode-3

Mode-4

BUZZER VOLUME

OFF

OFF

Quiet (*)

OFF

ON

Middle

ON

OFF

Loud

ON

ON

Maximum

• 

Output at the Loss of Communication: Mode-6

Mode-6

OUTPUT AT THE LOSS OF COMMUNICATION

OFF

Reset the output (turned off) (*)

ON

Hold the output (maintains the last data 
received normally)

Note: Be sure to set unused Mode-5 and 7 through 8 to OFF.

 

IP ADDRESS RESET

IP RESET SW

IP ADDRESS RESET

OFF

Operating (*)

ON

IP address returns to factory default 
(after restarting the unit)

(*) Factory setting
Note:  Other network settings are also reset to default.

 

CONFIGURATOR SETTING

Some network settings are available using the PC Configu-
rator Software. 
Factory default IP address  is 192.168.0.1.  IP address is 
configurable using the ITCFG on a PC.  In case that the 
changed IP address is not able for establishing a connection, 
reset the IP address to default and try to connect again. 
Note:  Refer to the ITCFG users manual for its instructions.