CHOOSING SUITABLE
SURROUNDINGS
In the room chosen to accommodate the
gas appliance, there must be an ade-
quate natural draft to allow combustion
of the gas.
The flow of air must come directly from
one or more openings made in the out-
side walls with a free area of at least 200
cm
2
.
The vents must be positioned close to
the floor, preferably on the opposite side
to the combustion discharge outlet and
must be designed in such a way that
they cannot be obstructed either from the
inside or the outside.
When it is not possible to provide the
necessary vents, the draft may be sup-
plied from an adjacent room, ventilated
in the required manner, provided it is not
a bedroom or an area at risk.
In this event, the door of the kitchen
must be opened to allow the draft to
enter the room.
H min 650
mm
Fig. 4.3
Fig. 4.4
Air vent
Air vent
Electric fan to
extract products
of combustion
Extractor hood
for products of
combustion
DISCHARGING PRODUCTS
OF COMBUSTION
Extractor hoods connected directly to
the outside must be provided, to allow
the products of combustion of the gas
appliance to be discharged (fig. 4.3).
If this is not possible, an electric fan may
be used, attached to the external wall or
the window; the fan should have a
capacity to circulate air at an hourly rate
of 3-5 times the total volume of the
kitchen (fig. 4.4).
The fan can only be installed if the room
has suitable vents to allow air to enter,
as described under the heading
“Choosing suitable surroundings”.