EM-5491-E1A  P. 2 / 4

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

• M8BS-8E1A-R

1

2

3

4

5

6

7

8

+ − + − + − + − + − + − + − + −

CH1

CH8

C D C D C D C D C D C D C D C D

CH8

CH1

A B A B A B A B A B A B A B A B

1 2 3

88 (3.46)

50 (1.97)

7.3 (.29)

240 (9.45)

260 (10.24)

280 (11.02)

32 - M3.5 INPUT TERMINALS

87 (3.43)

7.2 (.28)

16-M3.5

OUTPUT TERMINALS

17

CT PROTECTOR (CTR) 

*

1

POWER LED
CONNECTOR

CN1

3-M3.5 

POWER TERMINALS

8.6 (.34)

*

1. Included with M8CTx.

• M8BS-8E1A-K, KK, L

1

2

3

4

5

6

7

8

CH1

CH8

C D C D C D C D C D C D C D C D

CH8

CH1

A B A B A B A B A B A B A B A B

5

4

3

2

1

5

4

3

2

1

PWR1

PWR2

+ – + – + – + – + – + – + – + –

1

2

88 (3.46)

50 (1.97)

260 (10.24)

280 (11.02)

87 (3.43)

17 (.67)

POWER LED

*

3

CONNECTOR

CN1

7.2(.28)

16–M3.5

OUTPUT TERMINALS

106 (4.17)

POWER LED

*

2

POWER UNITS

*

1

5–M3

POWER TERMINALS

6

(.24)

32–M3.5 INPUT TERMINALS

7.3 (.29)

*

1. PWR2 provided only for two independent power sources.

*

2. Provided only for two independent power sources.

*

3. Provided only for single power source.

*

4. Included with M8CTx.

CT PROTECTOR (CTR) 

*

4

Summary of Contents for M8BS-8E1A

Page 1: ...DC rating 24V 10 0 7A GENERAL PRECAUTIONS Before you remove the unit from the base or mount it turn off the power supply and input signal for safety ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the installation base inside proper housing and ventilate it Do not install the base where it is subjected to continuous vibration Do not subject the unit to phys...

Page 2: ... M3 5 OUTPUT TERMINALS 17 CT PROTECTOR CTR 1 POWER LED CONNECTOR CN1 3 M3 5 POWER TERMINALS 8 6 34 1 Included with M8CTx M8BS 8E1A K KK L 1 2 3 4 5 6 7 8 CH1 CH8 C D C D C D C D C D C D C D C D CH8 CH1 A B A B A B A B A B A B A B A B 5 4 3 2 1 5 4 3 2 1 PWR1 PWR2 1 2 88 3 46 50 1 97 260 10 24 280 11 02 87 3 43 17 67 POWER LED 3 CONNECTOR CN1 7 2 28 16 M3 5 OUTPUT TERMINALS 106 4 17 POWER LED 2 POW...

Page 3: ... 36 ch 2 17 NC 37 NC 18 NC 38 NC 19 ch 6 39 ch 1 20 ch 6 40 ch 1 Toshiba DCS SAMP1 uses Panasonic AXM240001 As con nector is discontinued Omron XG4A 4031 is used as an al ternative Replace cable side CONNECTION DIAGRAM A B C D CN1 Ch 1 INPUT A B C D Ch 8 INPUT PWR2 4 5 FG 3 U V AC POWER PWR1 4 5 FG 3 U V AC POWER FG 3 2 1 A B C D CN1 Ch 1 INPUT A B C D Ch 8 INPUT DC Power Supply Single Power Suppl...

Page 4: ...different conditions HOW TO REPLACE THE POWER UNIT 1 Prepare Power Unit switching regulator model HDC6 2 K or HDC6 2 L 2 Turn off the power supply connected to the Power Unit 3 Detach the wire binding and remove the wiring connect ed to the power terminals 1 2 and 4 5 4 Loosen and remove the mounting screws A 4 places and the screws which fixing the Power Unit to the base plate 5 Detach the Power ...

Reviews: