Set the unit so that its DIN rail adapter is at the bottom.  
When the unit is installed to an Installation Base (model 
M6SBS), refer to its instruction manual.

 

 MOUNTING THE UNIT ON A DIN RAIL

A) Hang the upper hook at the rear side of unit on the DIN 

rail.

B) Push  in  the  lower  in  keeping  pressing  the  unit  to  the 

DIN rail.

 REMOVING THE UNIT

A) Pull  down  the  DIN  rail  adaptor  using  a  minus  screw

-

driver.

B) Pull out the lower part of the unit.
C) Remove the upper part from the DIN rail.

TERMINAL CONNECTIONS

Connect the unit as in the following diagram or refer to the connection diagram on the side of the unit.

 EXTERNAL DIMENSIONS  unit: mm (inch)

A

DIN Rail

B

A

DIN Rail Adaptor

C

B

INSTALLATION

94 (3.70)

5.9 (.23)

DIN RAIL

35mm wide

DIN RAIL HOOK

*

Use a minus screwdriver: tip width 3.8 mm max., tip thickness 0.5 to 0.6 mm

102 (4.02)

[0.5 (.02)]

SCREWDRIVER

INSERTION ANGLE

  : approx. 40°

WIRE INSERTION ANGLE

: approx.35°

TEST PROBE

max. 2 (.08) dia.

SCREWDRIVER 

*

INSERTION ANGLE

       : approx. 35°

5

6

7

8

1

2

3

4

• When mounting, no extra space is needed between units

.