background image

M1EXM-2

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-5983-A  Rev.1  P. 4 / 5

EXTERNAL VIEWS

Mode Button

Set Button

Display

Configurator Jack

Up Button

Down Button

COMPONENT

FUNCTION

Display

Indicates present values, setting values and abnormal information.  Two types of present values at up-
per and lower are displayed by setting.

Mode button

Used to shift from measuring mode to each setting mode.  Destination to shift is changed by the time 
pressing and holding the button.  Used to return from each setting mode to measuring mode (press and 
hold for 2 sec. or more).

Set button

Used to change setting value of setting parameter.  When at setting changeable state, used to enter 
(save) the setting value.  Used to move on through digits of setting value at setting changeable state.

Up button

Used to shift through setting parameter, and to increase or select setting value.

Down button

Used to shift through setting parameter, and to decrease or select setting value.

Configurator Jack

Used to configure with M1E configurator software (model: M1ECFG).  At the same time, set the lockout 
setting of the unit to ‘lock’.

WIRING INSTRUCTIONS FOR BASE

 

SCREW TERMINAL

Torque: 0.5 N·m

 

SOLDERLESS TERMINAL

Refer to the drawing below for recommended ring tongue 
terminal size.  Spade tongue type is also applicable.
Recommended manufacturer: Japan Solderless Terminal 
MFG.Co.Ltd, Nichifu Co.,ltd (Solderless terminals with in-
sulation sleeve do not fit)
Applicable wire size: 0.25 to 1.65 mm

2

12max

6max

3max

4min

3.2 dia.

(mm)

CHECKING

1) Terminal wiring:  Check that all cables are correctly con-

nected according to the connection diagram.

2) Power input voltage:  Check voltage across the terminal 

19 – 20 with a multimeter.

3) Input:  Check that the input signal is within 0 – 100% of 

the full-scale.

4) Output:  Check that the load resistance meets the de-

scribed specifications.

Summary of Contents for M1EXM-2

Page 1: ...validate the CE conformance The actual installation environments such as panel con figurations connected devices connected wires may af fect the protection level of this unit when it is integrated in a panel system The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conform ity Install lightning surge protectors f...

Page 2: ...ntiometer input 3 18 Unused 9 Ch2 Potentiometer input 2 19 Power U 10 Ch2 Potentiometer input 1 20 Power V INSTALLATION Pulling out the base while pushing the lockslider on the top of the unit enables to remove the base from the unit base is not included in the package DIN RAIL MOUNTING SIDE Mounting the unit A Hang the upper hook at the rear side of unit on the DIN rail B Push the lower part of t...

Page 3: ... of the unit EXTERNAL DIMENSIONS unit mm inch 125 4 92 36 1 42 89 3 50 5 20 5 20 7 28 7 28 45 1 77 4 16 DIN RAIL 35mm wide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Base is not included in the package MOUNTING REQUIREMENTS unit mm inch 99 3 90 2 M4 SCREW Mounting requirements for base CONNECTION DIAGRAM 11 12 14 15 19 20 CH1 OUTPUT CH1 POTENTIOMETER CH2 POTENTIOMETER 1 4 5 3 3 2 1 Max Min...

Page 4: ...p button Used to shift through setting parameter and to increase or select setting value Down button Used to shift through setting parameter and to decrease or select setting value Configurator Jack Used to configure with M1E configurator software model M1ECFG At the same time set the lockout setting of the unit to lock WIRING INSTRUCTIONS FOR BASE SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL...

Page 5: ...is out of accuracy perform the output fine adjustment Refer to the operating manual EM 5983 B when adjusting with front buttons Refer to the M1ECFG users manual EM 5981 when ad justing with M1E Configurator Software model M1ECFG And then follow the procedure shown below OUTPUT FINE ADJUSTMENT 1 Set the simulated input to 0 and adjust the output signal to 0 by 82 182 Output Zero fine adjust 2 Set t...

Reviews: