48NDM

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-9445-A  Rev.10  P. 5 / 8

FRONT PANEL CONFIGURATION

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

mA

100 SET

2

S

P

Z

1

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

Color Setpoint 2 Adj. & Function
Span Adj. & Setting

Decimal Point Position, Moving Average,

Brightness Adj.

Zero Adj. & Setting
Color Setpoint 1 Adj. & Function

Setting UP Button, Switcing Detailed Settings

Mode & Setting Selector

Setting DOWN Button, Switcing Detailed Settings

Digital Indicator

Setpoint 2 Value

Setpoint 1 Value

PV Indicator

M

Note: Setpoint 1 or 2 provided only for the multi-color bar type.

 ALARM OUTPUT CODE 0: None

• Bar Color Patterns

Pattern 1 (Bar LED color code 1)

orange

orange

green

orange

Input < L

L < Input < H

H < Input

green

red

H

L

Pattern 2 (Bar LED color code 2)

orange

green

green

red

red

red

H

L

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

mA

100 SET

H

S

P

Z

L

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

H Setpoint Adj. & Alarm Function
Span Adj. & Setting

Decimal Point Position, Moving Average,

Brightness Adj.

Zero Adj. & Setting
L Setpoint Adj. & Alarm Function

Setting UP Button, Switcing Detailed Settings

Mode & Setting Selector

Setting DOWN Button, Switcing Detailed Settings

H Setpoint

L Setpoint

PV Indicator

M

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

mA

100 SET

H

S

P

Z

L

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

HH Setpoint Adj. & Alarm Function
H Setpoint Adj. & Alarm Function
Span Adj. & Setting

Decimal Point Position, Moving Average,

Brightness Adj.

Zero Adj. & Setting
L Setpoint Adj. & Alarm Function
LL Setpoint Adj. & Alarm Function

Setting UP Button, Switcing Detailed Settings

Mode & Setting Selector

Setting DOWN Button, Switcing Detailed Settings

HH Setpoint

H Setpoint

L Setpoint

LL Setpoint

PV Indicator

HH

LL

M

 ALARM OUTPUT CODE 2: 2 points

Digital Indicator

 ALARM OUTPUT CODE 4: 4 points

Digital Indicator

Summary of Contents for 48NDM

Page 1: ...f fect the protection level of this unit when it is integrated in a panel system The user may have to review the CE or UKCA requirements in regard to the whole system and employ additional protective...

Page 2: ...TERED MOUNTING Not conform to degree of protection IP65 1 0 61 5 min USING BEZELS Bezels are used when the unit needs to be adapted to an ex isting panel cutout It is not required when the panel cutou...

Page 3: ...d below the unit for ventilation Bracket TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit EXTERNAL DIMENSIONS unit mm inch 75 2...

Page 4: ...BEZEL 2 10 4 41 7 5 30 3 9 15 136 5 5 37 144 5 67 11 4 45 7 5 30 4 9 19 136 5 5 37 144 5 67 8 5 33 10 4 41 7 5 30 136 5 5 37 144 5 67 OPTION F BEZEL 4 CONNECTION DIAGRAM 12 13 14 15 16 12 13 14 15 16...

Page 5: ...lor code 2 orange green green red red red H L 50 40 30 20 10 0 10 20 30 40 50 m3 h mA 100 SET H S P Z L 90 80 70 60 50 40 30 20 10 0 SET ENTER Button H Setpoint Adj Alarm Function Span Adj Setting Dec...

Page 6: ...elay for L Setpoint Increase Decrease Complete Digital Indicator SET L LL M Press at once ON Time Delay for LL Setpoint Increase Decrease Complete Digital Indicator SET LL Z M Press at once Zero Adjus...

Page 7: ...ched to continuous ON state 4 Press UP or DOWN buttons until the bargraph shows 100 and the digital indicator comes to a desired value and press SET DIGITAL INDICATOR SPAN ADJUSTMENT 1 Hold down M for...

Page 8: ...r calibration adjust the output as explained in the following HOW TO CALIBRATE THE OUTPUT INDICATION Use a signal source and measuring instruments of sufficient accuracy level Turn the power supply on...

Reviews: